Weber 55791 Thermometer User Manual


 
EC – DECLARATION OF CONFORMITY
This product contains the approved transmitter and complies with the essential
requirements of Article 3 of the R & TTE 1999/5/EC Directives, if used for its
intended purpose and that the following standard(s) has/have been applied:
Efcientuseofradiofrequencyspectrum:
(Article 3.2 of the R&TTE Directive)
applied standard(s) EN 300 220-3:2000
Electromagneticcompatibility:
(Article 3.1b of the R&TTE Directive)
applied standard(s) EN 301 489-3:2000
Safetyofinformationtechnologyequipment:
(Article 3.1.a of the R&TTE directive)
applied standard(s) EN 60950:2000
Additionalinformation:
The product therefore conforms to the Low Voltage Directive 73/23/EC, the EMC
Directive 89/336/EC and R&TTE Directive 1999/5/EC (appendix II) and carries the
respective CE marking.
RTTECompliantCountries
All EU countries, Switzerland, and Norway
CONNECTING THE PROBE
Locate the cover to the probe socket on
the top right side of the ThermoSensor
and carefully pull it out. Plug the meat probe into the socket.
OPERATION
Note:Onlyresetafterinstallingnewbatteries.
1.PressandholdpoweruntiltheThermoSensor’sredLEDashes.Thenpressand
hold power until the monitor’s green LCD lights and all display segments appear.
2. Repeatedly press “Select” until the desired meat appears. You can select BEEF,
LAMB, VEAL, HMBGR (Hamburger or rissoles), PORK, TURKY (Turkey), CHICK
(Chicken), or FISH. Then repeatedly press “Cook” to select doneness level.
Note:Thedonenesslevelselections,RARE,MEDRARE,MEDIUM,andWELL
DONE,areonlyavailableforbeef,lambandveal.Forchicken,pork,turkey,
shandhamburgerthemonitordefaultstoWELLDONE.
3. Place the ThermoSensor near the cooking area and insert the tip of the probe into
the center of the meat. To prevent the lid from crimping the probe wire, feed the
wire out through the slot on the side of the cookbox. Use the monitor’s stand for
easy viewing or use the belt clip. For charcoal grilling, route the probe wire away
from the direct heat of the charcoal briquettes.
Notes:
•PlacetheThermoSensorawayfromdirectheatorameanddonotrest
theprobeonthecookingsurface.Doingsocoulddamagethethermistor
insidetheprobe.
•Foraclearsignal,placethemonitorwithin100feetoftheThermoSensor.
•Theoperationtemperaturerangeofthesensorprobeis-4°Fto482°F(20°Cto
250°C).TheLCDdisplayrangeis0°C/Fto199°C/F.Whenthedisplaytemperatureis
outofrange,thedisplay’sdigitsash.
4.Whenthemeatisdone,removetheprobefromthemeatwearinganovenmittor
lettheprobecooloff.PressandholdPOWERonthemonitorandThermoSensor
for about 2 seconds to turn them off.
Notes:
•Themonitor’slastrecordremainsevenwhenyouturnthepoweroff.Whenyou
turn the monitor on again, the last record appears on the display.
•ThemonitorandThermoSensorautomaticallyturnoffityoudonotpressany
button for about eight hours.
5. Disconnect the probe from the ThermoSensor and replace the socket cover. After
younishcooking,cleantheprobewithwaterandamilddetergent.Wipethe
monitor and ThermoSensor with a damp cloth.
Note:Donotuseadishwashertocleantheprobeorimmersethemonitoror
ThermoSensorinwaterorliquid.
CHECKINGSIGNALSANDAUDIBLEALARMSTATUS
SIGNAL
Indicates no signal. Indicates the monitor is receiving a
signal from the ThermoSensor.
ALERTS
Threebeeps- indicates the monitor in not receiving a signal from the
ThermoSensor.
Fourbeeps-indicatesthecurrenttemperatureiswithinvedegreesofthetarget
temperature.
Acontinuousbeep- indicates the thermometer has reached its target temperature.
Afastandcontinuousbeep- indicates the meat is overcooked.
Note:Pressanybuttontostopthealert.
BATTERY NOTES
appears on the monitor to indicate the condition of the batteries. The following alerts
indicate when the batteries need to be replaced.
•
main - indicates the monitor’s battery is low.
• remote - indicates the ThermoSensor’s battery is low.
• main remote - indicates the batteries are low in both the monitor and
ThermoSensor.
• Use only fresh batteries of the required size and recommended type.
• Do not mix old and new batteries, different types of batteries (standard, alkaline or
rechargeable) or rechargeable batteries of different capacities.
• If you do not plan to use the thermometer with batteries for a month or more, remove
the batteries. Batteries can leak chemicals that can destroy electronic parts.
Weber-StephenProductsCo.,(Weber
®
) hereby warrants to the ORIGINAL
PURCHASER of this DigitalThermometer, that it will be free from defects in material
and workmanship from the date of purchase as follows: 2 year(s) when assembled,
and operated in accordance with the printed instructions accompanying it.
Webermayrequirereasonableproofofyourdateofpurchase.THEREFORE,YOU
SHOULDRETAINYOURSALESSLIPORINVOICEANDRETURNTHEWEBER
LIMITEDWARRANTYREGISTRATIONCARDIMMEDIATELY.
ThisLimitedWarrantyshallbelimitedtotherepairorreplacementofpartsthat
prove defective under normal use and service and which on examination shall
indicate,toWeber’ssatisfaction,theyaredefective.IfWeberconrmsthedefect
andapprovestheclaim,Weberwillelecttorepairorreplacesuchpartswithout
charge. If you are required to return defective parts, transportation charges must be
prepaid.Weberwillreturnpartstothepurchaser,freightorpostageprepaid.
ThisLimitedWarrantydoesnotcoveranyfailuresoroperatingdifcultiesdueto
accident, abuse, misuse, alteration, misapplication, vandalism, improper installation
or improper maintenance or service, or failure to perform normal and routine
maintenance. Deterioration or damage due to severe weather conditions such as hail,
hurricanes, earthquakes or tornadoes, discoloration due to exposure to chemicals
eitherdirectlyorintheatmosphere,isnotcoveredbythisLimitedWarranty.
Webershallnotbeliableunderthisoranyimpliedwarrantyforincidentalor
consequentialdamages.Thiswarrantygiveyouspeciclegalrights,andyoumay
also have other rights, which vary from state to state.
SPECIFICATIONS
Monitor
ThermoSensor
Batteries 2 x AA Batteries 2 x AAA
Operating temperature range Operating temperature range
32°Fto122°F(0°Cto50°C) -4°Fto140°F(20°Cto60°C)
Storage temperature range Storage temperature range
-4°Fto158°F(20°Cto70°C) 22°Fto158°F(-30°Cto70°C)
WaterResistance JISLevel2 Waterresistance JISLevel3
LCDDisplayRange 0°C/Fto199°C/F
General
Length of stainless steel probe 99.97cm (3.28 feet)
Transmit frequency 433MHz
Temperatureresolution +1°C(+-2°F)
Steelsensorprobe’soperatingtemperature Maximum250°C(482°F)
Specicationsaretypical;individualunitsmayvary.Specicationsaresubjectto
change and improvement without notice.
This symbol indicates that the product
cannot be disposed of in the trash. For
instructions regarding proper disposal of
this product in Europe, please visit www.
weber.com
®
, and contact the importer
listed for your country. If you do not have internet access, contact your
dealer for the importer’s name, address and telephone number.
FCC DECLARATION OF CONFORMITY
ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothe
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Product: Digital Thermometer
WeberPartNumber: 6438
ResponsibleParty: Weber-StephenProductsCompany
200 East Daniels Road
Palatine, IL 60067-6266 USA
Phone: 1-800-446-1071 (U.S.A. Only) www.weber.com
THEFCCWANTSYOUTOKNOW
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television reception,
which canbe determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
• Reorientorrelocatethereceivingantenna.
• Increasetheseparationbetweentheequipmentandreceiver.
• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe
receiver is connected.
• Consultanexperiencedradio/TVtechnicianforhelp.
• Ifyoucannoteliminatetheinterference,theFCCrequiresthatyoustopusing
your thermometer.
ChangesormodicationsnotexpresslyapprovedbyWeber-StephenProducts
Company may cause interference and void the user’s authority to operate
the equipment.
INSTALLING BATTERIES
The thermometer requires two AA batteries and two AAA batteries for power. Follow
these steps to install the batteries.
Note:ResetboththemonitorandtheThermoSensorwithin60seconds
tosynchronizethemtotransmitasignal.Onlyresetafterinstallingnew
batteries.
In The Monitor
1. Slide down and lift off the belt clip on the back of the
monitor. Slide then lift up and remove the battery
compartment cover.
2. Place two AA batteries in the compartment as
indicated by the polarity symbols (+ and -).
3. Press RESET in the battery compartment using a
pointedobjectsuchasastraightenedpaperclip.
4. Replace the cover and the belt clip.
In the ThermoSensor
1. Slide off the battery compartment cover.
2. Place two AAA batteries in the compartment as
indicated by the polarity symbols (+ and -) and
press RESET beside the battery compartment
usingapointedobjectsuchasastraightened
paper clip.
3. Replace the battery compartment cover.
When appears on the monitor, replace the batteries.
ADJUSTINGFAHRENHEIT/CELSIUS
ToselectFahrenheitorCelsius,slide°C/°F,locatedbesidethemonitor’sbattery
compartment,to°Cor°F.
ADJUSTINGTHEVOLUME
Toadjustthemonitor’svolume,slideHI/
LO, located in the ThermoSensor’s battery
compartment, to HI or LO.
LED INDICATOR
The red LED in the centre of the ThermoSensor
ashestoindicatethatitisonandtransmitting.
USINGTHEBELTCLIP
You can wear the belt clip on your belt or use it as
a stand. To use the belt clip as a stand, remove
the belt clip from the back of the monitor. Insert
the left or right side of the clip into the lower part of
the slot then snap the other side of the clip into the
other lower slot.
r
ese
t
"AAA"UM41.5V
Reset
ThermoSensor
reset
Hi/Lo C/F
"AA"UM31.5V
Reset
˚C/˚F
HI/LO
MonitorBatteryCompartment
BeltClipPosition
Stand
Position
select
cook
power
Levelsof
Doneness
Current
Temp
Select/Coo
k
Power
LowBattery
Indicator
IndicatorMonitor/
ThermoSensor
Communication
Typeof
Meat
Target
Temp
Power
ThermoSensorLED
Probe
ProbeSocket
Cover
Probe
Socket
(2)
(1)
DIGITAL THERMOMETER
SETUP
RemovethebatterycoversfromboththeThermoSensorandMonitor,then
removetheplastictabsfromthebatterycompartments.Continuetobattery
installationsteps.