Toshiba SL-9000-ESB-X SERIES Scale User Manual


 
14-10
14. OPERATING PROCEDURES
14.5 ISSUING LABELS WITH NET WEIGHT STATEMENT (FOR US TYPE ONLY)
NOTES: 1. To print NET WT. data. from the FIX mode, load a label which has an area to print a NET
WT Statement.
2. The quantity sold number and price data in NET WT. statement operation will be
accumulated in the memory. No weight data will be accumulated.
3. The position of the decimal point is adjustable and a comma or period is selectable by the
initial setting.
4. Weight data is shifted to the left.
5. Weight data exceeding 480 oz results in an error.
6. Unit price calculation system
(Step 1) Weight data is calculated from royal lb into decimal lb.
(Round off the data to two decimal places.)
ex.) 21 oz
1.3125 lb
round
1.31 lb
(Step 2) Price is divided by the value obtained above.
(Round off the data to two decimal places.)
ex.) 1.5$/1.31 lb = 1.145
round
$1.15/lb
This data is printed.
7. When the unit price is less than $0.01/lb or either the weight or price is 0, the unit price will
not be printed.
8. Multiplication registration of NET WT statement
The maximum quantity, of a commodity is 99.
In the following cases, an error occurs when pressing the
PRT/*
key to issue the label.
(1) Quantity = 0
(2) Price x quantity > max. price
Weight x pieces > max. tare (30 lb scale: 480 oz, 15 Kg scale: 9.995 Kg)
SELL BYPACKED ON
(Sample label)