Toshiba HT-201 Thermometer User Manual


 
How to Take Your Temperature How to replace the battery
Troubleshooting
How to Clean
How to Store
• The power turns on and the display indicates all symbols with a beeper sound.
• The previous value is displayed, and then “ ” is displayed.
• When the ambient temperature exceeds 33ºC, the product may display the ambient
temperature due to a warm measurement area.In such cases, turn off the power once and cool the measurement
area, and then take your temperature.
• The power is automatically shut down after a certain period of time lapse even if the operation button is
not pushed.
* If you want to measure your body temperature strictly, we recommend that you should take an actual body
temperature.Keep on taking your body temperature after the beeper sound in step 2 above. The actual temperature
measurement is successfully completed when the beeper sound goes off once again after approximately 5 minutes
lapse. Check the result of the actual measurement and continue with steps 3 and 4 above.
● Push the operation button of this Product at least 10 seconds while this Product is powered on.
Upon pushing the operation button even after this Product is powered off, four “□ ” are displayed and your body
temperature data in this Product is deleted. If you release the operation button before four “□ ” are displayed, the
data will not be deleted.
● Use a dry, soft cloth when removing stains from the product.
● Darker stains may be removed by using a soft cloth slightly moistened with water or alcohol.
●Please observe the following precautions. Cleaning this Product without observing the precautions may cause the trouble of this Product .
• The thermometer is not designed for fully waterproof. When removing stains, please be careful to prevent water and alcohol from entering into
this Product and keep them away from the display.
• Do not soak the measurement area in alcohol or water at than 50ºC or higher to sterilize it. Do not clean the measurement area by using ultrasonic cleaning.
• Do not use thinner, benzine, or abrasive cleaner to clean this Product.
• This Product is waterproofed from measurement area to 5cm away from it only. Keep the operation button and battery to prevent the water.
● Dry this Proudct by using a dry cloth before storing it in the storage case.
● If you do not intend to use this Product for a long period, be sure to remove the battery before storage.
● Storage in the places below may cause the trouble of this Product.
• Dusty places. Places subjected to direct sunlight, high-temperature or high-humidity. Places subjected to water or water splashes.
• Places where a corrosive gas is generated. Places subjected to vibration and shock.
• When a beeper sound goes off in approximately one minute and “ºC” is indicated on the display, an predictive
measurement is successfully completed.Check your body temperature measurement result
( predictive temperature value ).
• Measurement in an incorrect manner may result an incorrect measurement.
3.
1.
2.
4.
Completion of data deletion
Piii
PiPi PiPi
PiPi
Completion of estimation
measurement
Under taking a temperature
Previous value is displayed.
Estimation measurement starts.
Power Off (Blank screen)
Whole symbols on the screen
PiPiPi
PiPiPi
PiPiPi
Completion of actual
temperature measurement
Take Out this Product from the Storage Case. Push the Operation Button at least One Second.
Side of the Base of Your Tongue with the Display of this Product upwardly. Hold this Product
with Your Tongue and Shut Your Mouth. Hold this Product with Your Hand to prevent the
Mesurement Point in Your Mouth.
When this Product Displays “Lo” , Place the Measurement Area on Either the Right or Left
Turn Off the Power by Pushing the Operation Button for at least One Second.
Put this Product into the Storage Case.
■ Battery Replacement Procedure (CR2032 lithium battery × 1 pc)
■ Precautions in Replacing a Battery
1. Insert a Pointed Object, Such as a Tooth Pick, into the Hole on the Back Side
of this Product (Fig.1), Slide Out the Battery Cover by Using the Pointed
Object (Fig.2), andPull Out the Battery Cover (Fig.3).
2. Remove the Old Battery (Fig.4).
Product, And Then Set the New Battery with the “+” Side Upwardly (Fig.5).
Please do not insert a battery directly into this Product. It may cause trouble of this Product.
3. Wait for About at least approximately 10 Seconds to Prevent Malfunction of this
● Keep batteries and the battery cover away from small children to prevent their accidental swallowing.
● When disposing of a used battery, please follow all applicable laws and regulations in which it is being used.
● Replacing the battery deletes your body temperature data stored in this Product. Transfer the temperature data to your smartphone
before replacing the battery.
Actual Measurement
Delete your body temperature data in this Product
● Take your body temperature as soon as you wake up and while youare still in bed.
( Measurement after getting up or a meal may resultan incorrect measurement. )
Upon pushing the operation button, the remaining battery is indicated in four levels
promptly in accordance with the following procedures when “ ” is indicated.
you purchase this Product is for the temporary use and it may run out faster than usual.
4. Attach the Battery Cover So That the cover is Inserted into this Product (Fig.6).
5. Push the Operation Button and Check that “ ” is Displayed.
Measurement is impossible when “ ” is indicated.*Enclosed battery when
such as “ > > > ” (battery level low). Replace the battery
● Measurement should be conducted by using this Product at the same time every
morning to the extent possible
● Whenever you measure your body temperature by using this Product, please measure
the same point in your mouth
● If “ ” is displayed, data transfer to your smartphone is available.
For details, following web site : http://www.toshiba.co.jp/healthcare/bbt/en/index_e.htm
Transfer your body temperature data in this Product to your smartphone
Remaining battery symbol
[Display]
(6)
Hole (Two points)
Old battery
New battery
Wait for
10 seconds.
[Back Side of Main Unit]
(1)
(2)
(3)
(4)
(5)
Problem Probable Cause Remedy
Placed the measurement area in different
positions for each measurement or opened
your mouth during measurement.
See the “ For Correct Measurement ” and ” How To Take
Your Temperature ”.
“Er.03” is displayed.
Scattering in measurement
values
See the “ For Correct Measurement ”and ” How To Take Your
Temperature ”. A redictive measurement value is not correctly
estimated if the measurement area is taken out of your mouth
during predictive temperature measurement.
Keep on measurement ( foractual temperature measurement )
or turn off the power of this Product once and take your body
temperature again after at least 30 seconds lapse.
“Er.11 to 19” is displayed. Measurement has not been conducted in the
A trouble has occurred in this Product during
predictive temperature measurement.
correct manner.
See the “ For Correct Measurement ” and ” How To Take Your
Temperature ”.Turn off the power of this Product once and take
your body temperature again after at least 30 seconds lapse.
“A.Hi” is displayed. The thermometer has been stored in a place
where the temperature is higher than +40ºC.
Take your body temperature again after placing this Product in a
+10 to +40ºC environment for at least one minute
“A.Lo” is displayed. The thermometer has been stored in a place
where the temperature is lower than +10ºC.
Take your body temperature again after placing the thermometer in a
+10 to +40ºC environment for at least one minute .
“Hi” is displayed. The measurement result exceeded +42ºC.
See the “ For Correct Measurement ”and ” How To Take Your
Temperature ”.
“Lo” is displayed.
The measurement result was +33ºC or less.
See the “ For Correct Measurement ”and ” How To Take Your
Temperature ”.
Other than above cases. The thermometer has failed. Please visit our website for FAQ
Nothing is displayed on the
display.
The power can not be turned on.
● For support of this Product , please check our following site.
http://www.toshiba.co.jp/healthcare/bbt/en/index_e.htm
The battery has run out.
The thermometer has failed.
Battery of this Product is not properly seated. If power cannot be turned on, remove the battery once
and insert it again after 5 minutes lapse.
Replace the old battery with a new one. If the power
does not turn on even after the battery has been
replaced, please visit our website for FAQ