Toshiba EM1-31071 Scale User Manual


 
11-24
11. PROGRAMMING PROCEDURES
11.15 BAR CODE FORMAT
11.15 BAR CODE FORMAT
Menu Group: 2
Item No.: 6
With the SL-9000 scale, four kinds of bar code formats are available. These formats can be
changed freely.
Example)
Current format
Changed format
When changing the above example format into the weigh format described in NOTE 1, use the
following procedure.
C6C5C4C3C220
C/D
P4P3P2P1
PC/D
C5C4C3C2C192
C/D
P5P4P3P2C6
Flag UPC #
UPC #
Price Total check digit
Total check digit
Flag Price check digit or
weight check digit.
<MENU>
Group 2
ENTER
ENTER
1 1 2 3 4
2 3 4 5 6
6
or
NEXT
PLU
q
q
ESC.
PROG.
<MENU>
Group 2
Main
<MENU>
Set the flag.
(Left) (Right)
Enter a price
Enter an UPC #.
(Move the cursor to
the column to be set.)
Switch over the setting
item.(refer to NOTE 8)
ex)Press the key twice to
select UPC # as a setting
item.
Select the format #.
Format #1:WEIGH
Format #2:BY COUNT
Format #3:FIX PRICE
Format #4:RECEIPT
Switch over
UPC # PC/D
Set price
chech digit
Switch over
PC/D UPC #
ex)Enter "02"
NOTES: 1. In this printer, the previously set bar code format is initialized to the following default by
RAM clear.
Default Bar Code Format:
Weight or Fix Price Format
Bar Count Format
Receipt Format
C6C5C4C3C220
C/D
P4P3P2P1
PC/D
C5C4C3C2000
C/D
C60000
PC/D
000020
C/D
P5P4P3P2P1