Sunrise Medical 7305 Oxygen Equipment User Manual


 
A-704
International Travel / Introduction / Important Parts
3
English
WARNING
To reduce the risk of burns, electrocution, fire or injury to persons:
1. Close supervision is necessary when this product is used by, on, or near children or invalids.
2.
Use this product only for its intended use as described in this guide.
3. Never operate this product if
a. It has a damaged power cord or plug.
b
. It is not working properly.
c. It has been dropped or damaged.
d. It has been dropped into water.
Return th
e product to an authorized Sunrise Medical service center for examination and repair.
4. Keep the power cord away from heated surfaces.
5. Never use while drowsy or asleep.
NOTE– The 7305D series is not factory equipped with an internal rechargeable battery; it may be purchased separately and installed by your Sunrise Medical provider.
7305P series is factory equipped with an internal rechargeable battery and all information regarding battery operation in this guide is applicable.
DANGER
The DeVilbiss Suction Unit is a vacuum suction device designed for the collection of nonflammable fluid materials in medical applica-
tions only. Improper use during medical applications can cause injury or death. For all medical applications:
1. All suctioning should be done in strict accordance with appropriate procedures that have been established by a licensed medical authority.
2.
Some attachments or accessories may not fit the tubing supplied. All attachments or accessories should be checked prior to use to assure proper fit.
INTERNATIONAL TRAVEL
The 7305P series is equipped with a switch mode power supply allowing operation on any AC voltage (100-240 VAC, 50/60 Hz). However the correct
power cord must be used to connect to adaptable wall power.
NOTE– Check power cord for adaptability before using.
INTRODUCTION
Your DeVilbiss Suction Unit is a compact medical suctioning device which has been designed for reliable, portable operation. Because of the small
size, light weight and DC operation, the DeVilbiss Suction Unit is ideal for providing suction in the home, in transport with optional DC cord, or if
your model has an internal rechargeable battery, the unit can be operated anywhere. Two collection bottle options give the choice between the stan-
dard 800 ml disposable canister or an optional long-term reusable 1,200 ml canister. Following the recommended operating and maintenance proce-
dures outlined in this instruction guide will maximize the life of this product.
Intended Use Statement
The device is to be used to remove fluids from the airway or respiratory support system and infectious materials from wounds. The device creates a
negative pressure (vacuum) that draws fluids through disposable tubing that is connected to a collection bottle. The fluids are trapped in the collec-
tion bottle for proper disposal. It is for use on the order of a physician only.
IMPORTANT PARTS OF YOUR 7305 SERIES DEVILBISS SUCTION UNIT (refer to diagram)
Description
F
actory equipped on models:
1 Bacteria filter (non-sterile) All models
2 4" Connection tubing All models --
3
V
acuum gaug
e
All models
4 Tubing connector All models
5 Vacuum regulator knob All models
6
DC power input (on si
d
e) All models
7 Power switch All models
8 6' patient tubing All models --
9
80
0 cc disposable canister w/li
d All models
(float shut off incorporated into lid)
10 90° connection elbow All models
Switch m
od
e ad
apter
(not shown) All m
od
els
Internal rechargeable battery
(not shown) 7305P series
Carrying case
(not shown) 7305P series
NO
TE–
This unit compli
es with electr
omagnetic compatibility standards as defined in the included
Declar
ati
on o
f Conf
ormity
.
1
2
3
4
7
6
8
9
5
10
.25”ID x 6’ FDA approved PVC tubing
with connecting couplers. Use only
specified patient tubing for replacement.
8mmID FDA approved Silicone tubing.
Use only specified connection tubing
for replacement.