Suburban Mfg 12155-00-DREPAA Oxygen Equipment User Manual


 
Form No. 702703 Rev. E August, 2006 19
Owner’s Manual - Oxygen Therapy Door
Procedures
Nebulizer Assembly,
Complete
This is the complete nebulizer assembly including the bottle, cap,
regulator, extension, cotter pin, hose barb fitting and oxygen supply
hose (Figure 18).
Tool Required
Needle-nose pliers
P/N 212126
Procedure
1. On the nebulizer extension, use a needle-nose pliers to
squeeze the two ends of the cotter pin together, then
remove the pin from the extension (Figure 19).
2. Open the oxygen therapy door.
3. Place the nebulizer in the ice tray with the extension
through the opening in the door (Figures 19 and 20).
4. Inside the door, replace the cotter pin into the extension
to hold the nebulizer in place and spread the two cotter
pin ends apart to keep the pin from falling out.
Figure 18. Nebulizer Assembly, Complete
Bottle
Cap
Regulator
Hose Barb
Fitting
Cotter Pin
Extension
Oxygen
Supply Hose