Philips HB556 Light Therapy Device User Manual


 
Using the appliance
1 Check the distance between your body and the tanning appliance (min. 20 cm).
If necessary adjust the height and/or position of the tanning appliance.
2 Set the timer to the session time (fig. 15).
(Please refer to one of the tables in these instructions and to your own notes.)
3 Do not forget to put on the protective goggles provided.
As soon as the session time has elapsed the lamps will automatically be switched off.
If you wish to treat the other side of your body as well, you can set the timer again (it is necessary for the HB556 to cool down for 3
minutes before the lamp for the face tanner will restart again).
The facial tanner (HB556 only) can be switched on or off by 'B'.
Lying
1 Place the tanning appliance beside a bed or couch.
2 As the stand is on wheels you can draw the tanning appliance towards you while lying (fig. 16).
3 Ensure that the lamps are positioned straight above you.
4 After use, you can push the tanning appliance away from you to make getting up easier.
Sitting
1 Place a chair and the tanning appliance together (fig. 17).
2 Bring the tanning appliance in optimum position by turning the upper casing.
Standing
1 Turn the upper casing to bring it into a vertical position.
If necessary adjust the height.
2 Stand in front of the tanning appliance - at least 20 cm away (fig. 18).
Storage
The tanning appliance takes up very little space when stored in a vertical position (fig. 19).
Cleaning
Always unplug the tanning appliance and let it cool down before cleaning.
You can clean the outside of the tanning appliance with a damp cloth. Make sure that no water runs into the appliance.
Do not use abrasives or scourers.
Never use liquids such as alcohol, methylated spirits, petrol or acetone to clean the acrylic sheet as this may cause irreparable damage.
Replacement
The light emitted by the tanning lamps will become less bright in time (i.e. after a few years in case of normal use).When this happens, you will
notice a decrease in the tanning capacity of the appliance.You can solve this problem by setting a slightly longer tanning time or by having the
tanning lamps replaced.
Have the tanning lamps and/or starters replaced by a service centre authorised by Philips.They have the knowledge and skills required for this
job and the original spare parts for your tanning appliance.
If you really insist on replacing the tube lamps and/or starters yourself, you should proceed as follows:
1 First remove the mains plug from the wall socket.
2 Loosen the screws and remove the two end caps (fig. 20).
3 Pull out the acrylic sheet completely (fig.21).
After this, the lamps and starters are accessible.
4 Rotate the lamps slightly to the left or to the right.
5 When unlocked remove them from the lamp holders.
6 Remove the starters by turning slightly to the left and withdrawing.
7 To place new lamps and starters proceed in reverse order and direction.
8 Slide the acrylic sheet back into the profile.
Do not forget to fix the end caps by means of the screws.
B
Type HB556 only:The lamp of the facial tanner may only be replaced by service personnel authorised by Philips.
The tube lamps of tanning appliances contain substances which may pollute the environment.When discarding old tube lamps, please ensure
that they are separated from the normal household refuse and that they are disposed of at an officially assigned place.
Guarantee & service
If you need information or if you have a problem, please visit the Philips Web site at www.philips.com or contact the Philips Customer Care
Centre in your country (you will find its phone number in the worldwide guarantee leaflet). If there is no Customer Care Centre in your
country, turn to your local Philips dealer or contact the Service Department of Philips Domestic Appliances and Personal Care BV.
ENGLISH 9