SET UP
READING THE DISPLAY
Suggestions for Placement of the Unit
There is an opening on the back of the unit, which allows it to be easily
hung from the wall. In addition, a base is provided for the unit to be
placed on any surface in a standing position.
Since the humidity level within rooms can vary greatly, the Mold
Alert should be placed in an area most likely subject to mold growth.
Problem areas are often basements, closets, surfaces near windows
and exterior walls. Anywhere in a home that is damp or has suffered
from water damage is also a prime location for mold growth.
Three values of measurement are displayed simultaneously.
The left column shows the indoor relative humidity (%), the middle
columnindicatesroomtemperature(°C/°F),andtherightcolumn
displays the dew point (Td).
The temperature can be displayed either in Fahrenheit or Celsius by
adjustingthe°C/°Fswitchonthebackoftheunit.Theaudioalarmcan
beactivatedusingthe“AlOn/AlOff”switchonthebackoftheunit.
Riskofmoldformationoccursathumiditylevelsexceeding65%.When
this point is reached, the frowning face icon on the display will light up.
If the audio alarm is activated, it will also sound. An arrow pointing up
willbeashingnexttotherelativehumiditydisplay.Theaudioalarm
can be silenced by pressing any button.
When humidity levels are reduced below 65% the frowning face icon
willstopashingandthealarm(ifactivated)willbesilenced.Thearrow
pointing up display will persist to indicate high humidity levels have
occured in the past. The arrow pointing up display can be reset by
pressing any button.