Omega Engineering OS523E Thermometer User Manual


 
5
6
QUICK START
AVOID EXPOSURE
LASER RADIATION
IS EMITTED FROM
THIS APERTURE
LASER RADIATION - DO NOT STARE INTO BEAM
OUTPUT <1 mW, WAVELENGTH 630-670 nm
CLASS II (2) LASER PRODUCT, COMPLIES
WITH FDA 21CFR 1040.10 & EN60825-1/11.2001
®
OMEGASCOPE
CAUTION
Warning and
Certification
Label
OMEGASCOPE
®
Handheld Infrared
Thermometer
PATENT NOTICE This product may be protected by one or more of the
following patents: U.S. PAT. D357,194; B1 5,368,392; 5,524,984; 5,727,880;
5,465,838; 5,823,678; 5,823,679; 6,123,453; 6,267,500 B1; 6,341,891 B1; 6,377,400
B1; 6,540,398 B2 ; 6,614,830 B1; 6,633,434 B2; 6,659,639; / Canada 2,114,806;
2,116,055; 75811 D OMEGA ENGINEERING, INC./ Czech Republic 25372/ France 2
756 920; 2 767 921; 2,773,213; 0378411 to 0378446; 2 773 213 B1 / Germany M 94
06 478.4; G 94 22 197.9; G 94 22 203.7/ Italy RM940000913/ Japan 988,378/Holland
1007752; 25009-00/ Spain mod. ut. 0133292/ Slovak Republic 24565/ U.K.
Registered 2041153; 9726133.3/ EPO 0 644,408 B2; EP 1 085 307 A1. Other U.S. and
Foreign Patents Pending. Other U.S. and International Patents Pending.
MQS4088-0207
OS530LE
OS532E
OS533E
OS534E
OS530HRE
OS53x-CF
OS523E
OS524E
WARRANTY/DISCLAIMER
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in
materials and workmanship for a period of 25 months from date of
purchase of the base unit and 13 months from date of purchase on
Laser Sight Module. OMEGA’s WARRANTY adds an additional one (1)
month grace period to the normal one (1) year product warranty to
cover handling and shipping time. This ensures that OMEGA’s
customers receive maximum coverage on each product.
If the unit malfunctions, it must be returned to the factory for evaluation.
OMEGA’s Customer Service Department will issue an Authorized Return
(AR) number immediately upon phone or written request. Upon
examination by OMEGA, if the unit is found to be defective, it will be
repaired or replaced at no charge. OMEGA's WARRANTY does not apply
to defects resulting from any action of the purchaser, including but not
limited to mishandling, improper interfacing, operation outside of design
limits, improper repair, or unauthorized modification. This WARRANTY is
VOID if the unit shows evidence of having been tampered with or shows
evidence of having been damaged as a result of excessive corrosion; or
current, heat, moisture or vibration; improper specification;
misapplication; misuse or other operating conditions outside of
OMEGA’s control. Components in which wear are not warranted, include
but are not limited to contact points, fuses, and triacs.
OMEGA is pleased to offer suggestions on the use of its various
products. However, OMEGA neither assumes responsibility for any
omissions or errors nor assumes liability for any damages that
result from the use if its products in accordance with information
provided by OMEGA, either verbal or written. OMEGA warrants
only that the parts manufactured by the company will be as
specified and free of defects. OMEGA MAKES NO OTHER
WARRANTIES OR REPRESENTATIONS OF ANY KIND
WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE,
AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The
remedies of purchaser set forth herein are exclusive, and the total
liability of OMEGA with respect to this order, whether based on
contract, warranty, negligence, indemnification, strict liability or
otherwise, shall not exceed the purchase price of the component
upon which liability is based. In no event shall OMEGA be liable for
consequential, incidental or special damages.
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor
shall it be used: (1) as a “Basic Component” under 10 CFR 21 (NRC), used in
or with any nuclear installation or activity; or (2) in medical applications or
used on humans. Should any Product(s) be used in or with any nuclear
installation or activity, medical application, used on humans, or misused in
any way, OMEGA assumes no responsibility as set forth in our basic
WARRANTY/DISCLAIMER language, and, additionally, purchaser will
indemnify OMEGA and hold OMEGA harmless from any liability or damage
whatsoever arising out of the use of the Product(s) in such a manner.
RETURN REQUESTS/INQUIRIES
Direct all warranty and repair requests/inquiries to the OMEGA Customer
Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA,
PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER
FROM OMEGA’S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO
AVOID PROCESSING DELAYS). The assigned AR number should then be
marked on the outside of the return package and on any correspondence.
FOR WARRANTY
RETURNS,
please have the following
information available BEFORE
contacting OMEGA:
1. Purchase Order number under
which the product was
PURCHASED,
2. Model and serial number of
the product under warranty, and
3. Repair instructions and/or
specific problems relative to
the product.
FOR NON-WARRANTY REPAIRS,
consult OMEGA for current repair
charges. Have the following
information available BEFORE
contacting OMEGA:
1. Purchase Order number to cover
the COST of the repair or
calibration,
2. Model and serial number of the
product, and
3. Repair instructions and/or specific
problems relative to the product.
OMEGA’s policy is to make running changes, not model changes,
whenever an improvement is possible. This affords our customers the
latest in technology and engineering.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2007 OMEGA ENGINEERING, INC. All rights reserved.
This document may not be copied, photocopied, reproduced, translated, or
reduced to any electronic medium or machine-readable form, in whole or in
part, without the prior written consent of OMEGA ENGINEERING, INC.
Shown with
Built-in Distance
Measuring Option
and Digital Video
Camera Attachment
TM
Functional Flow Chart when the Trigger is Pulled (Real Time Mode)
Press to... to...
Press or to...
FUNC
LOCK
F
C
F
C
DISPLAY
MODE:
Press
Display shows:
Emissivity
Go to
Set Emissivity
Current temperature Lock or unlock
Distance (feet or meter)
Go to
Trigger LCK
Current temperature
Laser status
Go to
Set laser to
Current temperature Flashing or On
Maximum temperature
Go to
Press to turn on/off
Current temperature LCD backlight
Minimum temperature
Go to
Current temperature Reset Maximum, Press to change
Differential temp
Go to
Minimum, Diff.
from °F to °C or feet to meter
Current temperature
Average temps and vise versa
Average temperature
Go to
Current temperature
High alarm set point
Go to
Enable/Disable
Set High Alarm set point
Current temperature HAL
Thermocouple temp
Go to
–––––– Turn on LCD Back lite
Current temperature Change °F to °C
Low alarm set point
Go to
Enable/Disable
Set Low Alarm set point
Current temperature LAL
Ambient target temp
Go to
Enable/Disable
Set Ambient Target temp
Current temperature ATC
Data Trans. Interval
Go to
Enable/Disable
Set Data Transmission
Current Temperature PRN interval (Logging)
Memory location
Go to Store temp data –––
Current temperature
Logging
Go to
Turn on/off
–––
Current temperature Logging
Real Time Modes
NOTE: The unit of measure (°F or °C) flashes during Real Time Mode.
OS530LE, OS530HRE
OS532E
OS533E
OS534E, OS523E, OS524E
LCK
LAL
ATC
PRN
MODE MODEDISPLAY DISPLAY
LCK
LCK
LCK
LCK
LCK
LCK
LCK
LCK
LCK
LCK
LCK
LCK
HAL
LCK
LCK
(Models OS530LE,
OS530HRE)
(Models
OS534E,
OS523E,
OS524E)
(Model OS533E)
(Model OS532E)
on
FUNC
FUNC
FUNC
FUNC
FUNC
FUNC
FUNC
FUNC
FUNC
FUNC
FUNC
FUNC
FUNC
FUNC
*
*
*
*
*
*
*
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI
regulations that apply. OMEGA is constantly pursuing certification of its products to
the European New Approach Directives. OMEGA will add the CE mark to every
appropriate device upon certification.
The information contained in this document is believed to be correct but OMEGA
Engineering, Inc. accepts no liability for any errors it contains, and reserves the right
to alter specifications without notice.
WARNING: These products are not designed for use in, and should not be used for,
patient connected applications.
CAUTION
There should be a clean, open line of sight from the distance device to the
target, otherwise an erroneous reading will result.
For accurate distance measurement readings, the surface must be hard,
flat, and reflective to ultrasonic pulse.
• Distance measurement can not be taken through glass, or off of soft and
padded surfaces, or through smoke or fog.
The distance measurement unit must be held perpendicular to the target
surface.
The distance measurement unit is designed for indoor use only.
Accuracy of the distance measurement unit will vary depending on
environmental conditions.
Do not aim the distance measurement unit.
OMEGAnet
SM
On-Line Service Internet e-mail
omega.com info@omega.com
Servicing North America:
USA: One Omega Drive, P.O. Box 4047
ISO 9001 Certified
Stamford CT 06907-0047
Tel: (203) 359-1660
FAX: (203) 359-7700
e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1
Tel: (514) 856-6928
FAX: (514) 856-6886
e-mail: info@omega.ca
For immediate technical
or application assistance:
USA and Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Canada: Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico: En Espan˜ol: (001) 203-359-7803
e-mail: espanol@omega.com
FAX: (001) 203-359-7807
info@omega.com.mx
Servicing Europe:
Czech Rudé armády 1868, 733 01 Karviná 8
Republic: Tel: +420 (0)69 6311899
FAX: +420 (0)69 6311114
Toll Free: 0800-1-66342
e-mail: czech@omega.com
Germany/ Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Austria: Tel: +49 (0)7056 9398-0
FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 639 7678
e-mail: germany@omega.com
United One Omega Drive, River Bend Technology Centre
Kingdom: Northbank, Irlam, Manchester
ISO 9002 Certified
M44 5EX United Kingdom
Tel: +44 (0)161 777 6611
FAX: +44 (0)161 777 6622
Toll Free in United Kingdom: 0800-488-488
e-mail: sales@omega.co.uk
For latest product manuals: omegamanual.info