Omega Speaker Systems OSXL653 Thermometer User Manual


 
9
4-4-2 Max, Min, Avg, ∆T Temperatures
You can review the Maximum, Minimum, Average,
and differential (Max - Min) temperatures on the
display by pressing the F key. If the trigger is pulled
at the same time, the display will show SCAN icon
and all the values are in real time. If the trigger is
released, the display will show the HOLD icon and
all the values are the last readings before the trigger
is released.
4-4-3 Temperature Data Storage &
Recall - DATA Mode (OSXL653)
You can store up to 10 temperature data points
(Memory Location 0 thru 9). When you are in DATA
mode, set the memory location using the Up or
Down keys, then pull the trigger. The unit will store
the temperature data in the next memory location.
You can review (recall) the stored data by going to
the DATA mode using the F key (Trigger is released)
and pressing the UP/Down keys. You can then
review memory locations 0 thru 9.
The unit stores all temperature data, Emissivity
value, high and low alarm set points in the
non-volatile memory, Changing the battery will not
affect these values.
NOTE
Low Cost Professional Infrared Thermometer
(OSXL653)