Olympus CKX41 Microscope & Magnifier User Manual


 
CKX41/CKX31 dimensions (unit: mm)
Specifications are subject to change without any obligation on the part of the manufacturer.
ISO9001
Certification
Design and production
adheres to ISO9001
international quality standard.
ISO 9001
Accredited by the
Dutch Council for
Accreditation
ISO14001
Design and production at the Olympus
Optical Co. Ltd. Ina Plant conforms with
ISO14001 specifications for
environmental management systems.
Certification
ISO 14001
008
UKAS
ENVIRONMENTAL
MANAGEMENT
Item CKX41 CKX31
Optical system UIS (Universal Infinity-corrected) optical system
Focus Vertical nosepiece movement (stage is fixed),
coaxial coarse and fine focus with tension adjustment mechanism, roller slide mechanism,
stroke: 7mm up and 2mm down from focus position which is 1mm above the stage,
stroke per rotation: 39.6mm (coarse), 0.2mm (fine)
Revolving nosepiece Quadruple
Stage Plain stage 160mm(L) x 250mm(W), stage clips attachable
Exchangeable insert plate (ø25mm opening) incorporated ø35 petri dish holder stage
incorporated
Mechanical stage Right-hand low drive coaxial controls,
stage movement: X=120mm, Y=78mm, with three dish/sample holders
Substage 70(L) X180(W)mm
Illumination Light source 6V,30W halogen lamp, lamp socket (U-LS30-3-2),
system built-in frosted and heat absorbing filters, detachable illuminator
Filter holder Insert up to 11mm thick with ø45mm filter, detachable
Aperture diaphragm Lever type, range: from minimum ø3mm to maximum ø44mm
Slider insertion With phase slider pocket and built-in slider position click stop mechanism
Condenser Detachable ultra-long working distance condenser (N.A. 0.3, W.D. 72mm)
Contrast slider Pre-centered phase-contrast: 4X, 10X/20X/40X, empty slot
Centerable phase-contrast: 4X, 10X/20X, empty slot (40X optional, pre-centered)
Centerable for Relief Contrast: 10X, 20X, 40X
Observation Binocular tube U-CBI30-2: inclined 30°, interpupillary distance range: 48-75mm,
tube diopter adjustment by helicoid on left sleeve (F.N. 20)
U-BI30-2: inclined 30°, interpupillary distance range: 48-75mm,
diopter adjustment by helicoid on left sleeve (F.N. 22)
Trinocular tube U-CTR30-2: inclined 30°, ring dovetail attachment,
interpupillary distance range: 48-75mm, tube length
and diopter adjustment by helicoid on left sleeve
Observation optical path: 50(binocular)/50(video port) (F.N. 20)
U-TR30-2: inclined 30°, ring dovetail attachment,
interpupillary distance range: 48-75mm, tube length
and diopter adjustment by helicoid on left sleeve
Observation optical path: 50(binocular)/50(video port) (F.N. 22)
Tilting binocular CKX-TBI: variable inclination angles from 30° to 60°,
tube interpupillary distance range: 50-76mm,
diopter adjustment by helicoid on right sleeve (F.N. 20)
UTBI-3: variable inclination angles from 5° to 35°, circular
mounting dovetail attachment, interpupillary distance range:
50-76mm, diopter adjustment by helicoid on right sleeve. (F.N. 22)
Fluorescent illuminator Detachable illuminator,
switchable slide (3-position: B excitation, G excitation, empty slot or U excitation)
FL light source 50W Hg
FL light shutter Available
FL field stop Available
FL cubes 2 cubes (B & G), option U
(cubes are not compartible with UIS. Filter and dichroic mirror size are same as UIS)
Filter 1 filter
Eyepiece For U-CBI30-2/U-CTR30-2/CKX-TBI: WHB10X/WHB10X-H (F.N. 20) 10X (F.N.: 20)
For U-BI30-2/U-TR30-2/U/TBI3: WH10X/WH10X-H/35WH10X/
PWH10X (F.N. 22)
Power supply Continuous intensity adjustment,
built-in voltage changeover switch (100/120V, 220/240V), frequency 50/60Hz
CKX41/CKX31 specifications
Objective N.A. W.D.(mm) Remarks
PLC4X 0.10 22.0
PLC10X 0.25 10.5
ACH20X 0.40 3.0
LCPLFL40X 0.60 2.6
UPLFL4XPH 0.13 17.0 PHL (for use with IX2-SL)
CPL10XPH 0.25 9.8 PHC (for use with IX2-SL)
PL10XPH 0.25 10.5 PH1 (for use with IX2-SL)
LCACH20XPH 0.40 3.2 PHC (for use with IX2-SL)
LCPLFL20XPH 0.40 6.9 PH1 (for use with IX2-SL)
LCACH40X2PH 0.55 2.2 PH2 (for use with IX2-SL)
LCPLFL40XPH 0.6 2.6 PH2 (for use with IX2-SL)
UPLFL4XPHP* 0.13 17.0 For use with IX2-SLP
CACH10XPHP* 0.25 8.8 For use with IX2-SLP
LCACH20XPHP* 0.40 3.2 For use with IX2-SLP
LCACH40XPHP* 0.55 2.2 For use with IX2-SLP
CPL10XRC 0.25 9.5 For use with CKX-RC
LCACH20XRC 0.4 2.8 For use with CKX-RC
LCACH40XRC 0.55 1.9 For use with CKX-RC
UPLFL4X 0.13 17 U,B,G
UPLFL10X 0.3 10 U,B,G
UPLFL20X 0.5 1.6 U,B,G
LCPLFL20X 0.4 6.9 B,G
LUCPLFL40X 0.6 2.7 - 4.0
Objective lens specifications
For brightfield
For phase-contrast
For RC
For FL
* Pre-centering objective
Fixed binocular tube, inclined
45°, interpupillary distance range:
48-75mm, diopter adjustment by
helicoid on right sleeve
237.6
195
393.1
515.5
473.7
370.5
364
194.5
237.6
473.2
380.5
486.6
370.5
364