Appendix A:
A-1: Tentative Selection of Motor Capacity
Temporarily select the motor capacity at first while taking into account the following two points,
and determine the model.
The rated torque of the motor should be larger than the effective torque.
The load inertia moment should not exceed approximately 10 times of the inertia moment of
the motor itself.
Positioning Control