Kohler K-1220-AC Bathroom Aids User Manual


 
1.25>132
16”
1-3/8”
8-3/8”
60”
FIELD WIRING COMPARTMENT
PUMP
PUMP/CONTROL ACCESS
32”
2-7/8”
3”
1-1/2” I.P.S. THR’D
1-1/2” O.D.
20”
3/8”
1-1/2”
2-3/4”
6
106548-CA (9437)
Kohler Co., Kohler WI
2. ROUGHING-IN: K-1205-AC, K-1206-AC
A. ORDERING INFORMATION
Factory installed components include pump and air switch
transmitter.
Information contained in this roughing-in also applies to
K-1206-J1-AA, K-1206-J1-AB and K-1206-JA-AA.
Whirlpool with wall timer K-1205-AC
Whirlpool with air actuator (shown) K-1206-AC
Accessories/hardware:
Drain K-7161-AF recom-
mended
Vinyl tiling-in bead* K-1177 optional
*Use K-1177 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control 120 V., 15 A, 60 Hz
C. PRODUCT INFORMATION
Fixture: basin area top area weight
Bathing well 44” x 22” 55” x 25” 100 lbs.
water depth capacity
To overflow 15-1/8” 60 gals.
Pump: hp V Hz A
60 Hz 1/2 120 60 8
D. INSTALLATION NOTES
Refer to installation instructions included with fixture before
beginning installation.
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to toler-
ances in ANSI Standard Z124.1.
No change in measurements if connected with drain
illustrated.
Cut-out 30-1/2” x 58-1/2”
Minimum access:
Pump/control box 20” W x 15” H panel required