4. ROUGHING-IN: K-1215-AC, K-1216-AC
A. ORDERING INFORMATION
Factory installed components include pump and air switch
transmitter.
Information contained in this roughing-in also applies to
K-1216-J1-AA and K-1216-JA-AA.
Whirlpool with wall timer K-1215-AC
Whirlpool with air actuator (shown) K-1216-AC
Accessories/hardware:
Drain K-7161-AF recom-
mended
Vinyl tiling-in bead* K-1179 optional
*Use K-1179 vinyl bead when wall material contacts any
top surface of bath.
B. REQUIRED ELECTRICAL SERVICE
Dedicated circuits required, protected with Class A
Ground-Fault Circuit-Interrupter (GFCI):
Pump/control 120 V., 15 A, 60 Hz
C. PRODUCT INFORMATION
Fixture: basin area top area weight
Bathing well 52” x 23” 65-1/2” x
26-1/2”
95 lbs.
water depth capacity
To overflow 15-1/2” 76 gals.
Pump: hp V Hz A
60 Hz 3/4 120 60 10
D. INSTALLATION NOTES
Refer to installation instructions included with fixture before
beginning installation.
*Some K-1179 tiling-in beads may require trimming of the
bottom edge for proper fit.
ROUGHING-IN NOTES
Fixture dimensions are nominal and conform to toler-
ances in ANSI Standard Z124.1.
No change in measurements if connected with drain
illustrated.
Cut-out 34-1/2” x 70”
Minimum access:
Pump/control box 20” W x 15” H panel required