CONFIGURATION PROCEDURES
CodeXML Protocol Compatibility
The CodeXML protocol does not support page/disconnect button functions, or
scanner firmware upgrades through the access point device and Metroset2.
When a scanner is using the CodeXML protocol, configuration data is stored in
the scanner. The stored data is not transmitted to the access point device.
Special configuration steps are required for the customization of system formats
and protocols. Instructions on how to configure a scanner in the CodeXML
protocol mode via the access point device are outlined on page 11.
CodeXML Firmware Requirements
Scanner Model Firmware Version
Focus BT 15701 or higher
To configure a scanner to use the CodeXML protocol:
1. Scan the Disable Metrologic Protocol bar code.
Disable Metro Protocol
³125604
2. Scan the Recall Defaults bar code.
Recall Defaults
³999998
3. Scan the Enable CodeXML Protocol bar code.
Enable CodeXML Protocol
³125617
4. Scan the address bar code located on the top of the access point device
(see Figure 11, on page 8) to establish a communication link between the
scanner and access point.
5. The scanner will beep to indicate a connection has been established.