HoMedics BPS-060 Blood Pressure Monitor User Manual


 
3029
TROUBLESHOOTING
If any abnormality arises during use, please check the following points
Note: If the unit still does not work, contact HoMedics Consumer
Relations. Under no circumstance should you disassemble or
attempt to repair the unit by yourself. Contact information for
HoMedics Consumer Relations Department can be found on
the warranty page.
SYMPTOMS
POSSIBLE
CAUSES
CORRECTION
Unit does not turn on
when the
START/STOP
button is pushed.
Batteries have
run down.
Replace them with
two new AA alkaline
batteries.
Battery polarities
have been positioned
incorrectly.
Re-insert the batteries
in the correct
positions.
EE measurement
error symbol shown
on display or the
blood pressure value
is displayed
excessively low
(or high).
Cuff has been placed
incorrectly.
Wrap the cuff
properly so that it is
positioned correctly.
Did you talk or move
during measurement?
Measure again.
Keep arm steady
during measurement.
Shaking of the arm
with the cuff on.
E1 error symbol
shown on display
Air circuit abnormality.
Cuff tube may not be
plugged into monitor
correctly.
Check cuff connection.
Measure again.
E2 error symbol
shown on display
Inflation pressure
exceeding 300 mmHg.
Turn the unit off, then
measure again.
E3 error symbol
shown on display
Error determining
measurement data.
Measure again.
CA appears on
display
Recalibration alert.
Refer to page 25 for
more information.
P
P
o
o
w
w
e
e
r
r
S
S
o
o
u
u
r
r
c
c
e
e
:
:
Four 1.5V DC (AA) batteries
M
M
e
e
a
a
s
s
u
u
r
r
e
e
m
m
e
e
n
n
t
t
M
M
e
e
t
t
h
h
o
o
d
d
:
:
Oscillometric
M
M
e
e
a
a
s
s
u
u
r
r
e
e
m
m
e
e
n
n
t
t
R
R
a
a
n
n
g
g
e
e
:
:
Pressure: 40~280 millimeters mercury (mmHg)
Pulse: 40~199 beats/minute
A
A
c
c
c
c
u
u
r
r
a
a
c
c
y
y
:
:
Pressure: ±3 mmHg
Pulse: ±5% of reading
P
P
r
r
e
e
s
s
s
s
u
u
r
r
e
e
S
S
e
e
n
n
s
s
o
o
r
r
:
:
Semi-conductor
I
I
n
n
f
f
l
l
a
a
t
t
i
i
o
o
n
n
:
:
Manual Inflation
D
D
e
e
f
f
l
l
a
a
t
t
i
i
o
o
n
n
:
:
Automatic Pressure release valve
M
M
e
e
m
m
o
o
r
r
y
y
C
C
a
a
p
p
a
a
c
c
i
i
t
t
y
y
:
:
60 memories
A
A
u
u
t
t
o
o
-
-
s
s
h
h
u
u
t
t
-
-
o
o
f
f
f
f
:
:
1 minute after last button operation
O
O
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
E
E
n
n
v
v
i
i
r
r
o
o
n
n
m
m
e
e
n
n
t
t
:
:
Temperature: 50°F~104°F (10°C ~40°C)
Humidity: Less than 85% R.H.
S
S
t
t
o
o
r
r
a
a
g
g
e
e
E
E
n
n
v
v
i
i
r
r
o
o
n
n
m
m
e
e
n
n
t
t
:
:
Temperature: -4°F~140°F (-20°C~60°C)
Humidity: Less than 85% R.H.
W
W
e
e
i
i
g
g
h
h
t
t
:
:
.40 lbs/181 grams (without batteries)
A
A
r
r
m
m
C
C
i
i
r
r
c
c
u
u
m
m
f
f
e
e
r
r
e
e
n
n
c
c
e
e
:
:
Standard size adult arm cuff:
9"–13" (23 – 33 cm)
D
D
i
i
m
m
e
e
n
n
s
s
i
i
o
o
n
n
s
s
:
:
4.9"(L) x 4"(W) x 2.5"(H)
125mm(L) x 102mm(W) x 63mm(H)
Type BF
Device and cuff are designed to provide
special protection against electrical shocks.
SPECIFICATIONS
Note: These specifications are subject to change without notice.