Graco 24B795 Microscope & Magnifier User Manual


 
Installation
4 313840G
Installation
Prepare to Install
1. Relieve the pressure. Follow instructions in your
Operation manual.
2. Disconnect the air line to the pump.
Install the Kit
1. Mount the bracket
to the wall. Use
approximately
3/8 in. bolts or
screws.
2. Install the DataTrak
module (1) on the
bracket.
3. Conversion Kits include a new air valve that is com-
patible with the solenoid. Remove the old air valve
and gasket from the pump, and install the replace-
ment air valve and gasket.
4. Select the Diagnostic Codes card that matches the
operator’s preferred language. Insert it in the inside
of the DataTrak cover for quick reference.
5. DataTrak with runaway protection: Attach the sole-
noid (S) and bracket (4d) to the air valve. Use the
same screws (4c) that attach the air valve to the
manifold, as shown.
SPECIAL CONDITIONS FOR SAFE USE
Equipment must comply with the following
conditions to avoid a hazardous condition
which can cause fire or explosion.
All label and marking material must be
cleaned with a damp cloth (or equiva-
lent).
The electronic monitoring system is
required to be grounded. See Ground-
ing instructions in your pump operation
manual.
WARNINGWARNINGWARNING
WARNING
1
ti14055a
ti14223a
ti14058a
S
4d
4c