DataTrak Operation
10 313840G
Table 1: Diagnostic Codes
Symbol Code Code Name Diagnosis Cause
Runaway Pump running faster than
set runaway limit.
Increased air pressure.
Increased fluid output.
Exhausted fluid supply.
E-3 Low Battery Battery voltage too low to
stop runaway.
Low battery. Replace battery;
see page 11.
E--4 Service
Component 1
Problem with stopping
runaway.
Damaged solenoid.
Damaged valve carriage.
Runaway protection may be
enabled with pump that is not
equipped with a runaway sole-
noid valve. Enter setup screen
and disable runaway protec-
tion.
E-4 Disconnected
Solenoid
Solenoid is disconnected. Solenoid unplugged.
Damaged solenoid wires.
E-6 Blown Fuse Fuse is blown. Replace
fuse; see page 11.
Faulty solenoid or solenoid
wiring.
Extreme temperatures (above
140°F [60°C]).
Runaway protection may be
enabled with pump that is not
equipped with a runaway sole-
noid valve. Enter setup screen
and disable runaway protec-
tion.