DataTrak Operation
313840G 9
Calibration Procedure
1. Press and hold for 5 seconds until Setup menu
appears.
2. Press once. Change flow rate units to
cycles/min.
3. Return to Run Screen. Press and hold for three
seconds to reset batch totalizer.
4. Dispense fluid from pump into a graduated con-
tainer.
5. Convert the actual volume dispensed to cubic centi-
meters (cc). See conversion chart.
6. Divide the actual volume dispensed (cc) by the num-
ber of cycles indicated on the DataTrak batch total-
izer display.
7. Press to enter the Setup screen. Enter the
number from Step 6 in field 2 of the Setup screen.
Units Measured Multiply by To get
Gallons (U.S.) 3785 cc
Gallons (Imp) 4546 cc
Liters 1000 cc
Quarts 946 cc
Ounces (U.S.) 29.57 cc
Ounces (Imp) 28.41 cc
Cubic inches 16.39 cc
Cubic feet 28,317 cc
Pints 473 cc
cc 1 cc