Graco 204124 Personal Lift User Manual


 
3306522
Installation
Locating the Elevator (Fig. 1)
1. Provide sufficient clearance in front of the elevator
to change drums.
2. The ceiling must be at least 6 ft. (1.8 m) high for
the elevator to be fully raised.
3. Be sure the air supply lines to the pump and
elevator and the fluid outlet line from the pump can
be brought to the site. Use several feet of hose
between the pump and its supply lines to allow the
pump to be raised and lowered.
Installing the Elevator (Fig. 1)
1. Use 3/8 in. size bolts (A) which are long enough to
firmly secure the elevator base (110) to the con-
crete floor. Use shims as necessary to level the
base. Ensure that the elevator tube is in a true
vertical position.
2. Position a 120 lb lubricant drum so that it is touch-
ing the elevator base (110).
3. Loosen the screws (202) and nuts (203) on the
bracket (204). Position the drum cover (207)
squarely on the drum bead. Lightly tighten the
screws and nuts.
Mounting the Pump
1. Mount a Fire-Ball
R
or Fast-Flo
R
pump on the
bracket.
2. Refer to your separate pump instruction manual for
further information on system accessories and
installation.
06543b
Fig. 1
114
202,
203
204
111
110
A
207
Raised
71in.
(1803 mm)
Lowered
41.75 in.
(1060 mm)
108
0.25 in.