Golden Technologies GP204 Wheelchair User Manual


 
Alante DX/LT Owner’s Manual Rev A_011811
VII. OPERATION – cont.
1.4 Battery Gauge Flashes Rapidly
(
even with the joystick released
)
The control system safety circuits have operated and the control system has been
prevented from moving the wheelchair. This indicates a system trip, i.e. the VR2 has
detected a problem somewhere in the wheelchair’s electrical system.
Please follow this procedure:
Switch off the control system.
Make sure that all connectors on the wheelchair and the control system are
mated securely.
Check the condition of the battery.
If you can’t find the problem, try using the self-help guide given in section 1.6.
Switch on the control system again and try to drive the wheelchair. If the safety
circuits operate again, switch off and do not try to use the wheelchair.
Contact your Golden Technologies representative for service.
1.5 Self-Help Guide
If a system trip occurs, you can find out what has happened by counting
the number of LEDs on the battery gauge that are flashing.
Figure 27
28
Battery Gauge