Genie GR-12 Wheelchair User Manual


 
Operator's Manual Third Edition • Second Printing
2 GR-12 • GR-15 • GR-20 Part No. 97779
Tip-over Hazards
Occupants, equipment and materials must not
exceed the maximum platform capacity. Weight in
trays and in each bike rack is part of the total
platform load.
Maximum capacity - GR-12 and GR-15
Standard platform 227 kg
Work station tray (option) 22 kg
Parcel tray (option) 68 kg
Maximum occupants 1
Stock Picker platform 227 kg
Adjustable work station tray 68 kg
Parcel tray (option) 68 kg
Bike rack (option) (each) 20 kg
Maximum occupants 1
AWP and fiberglass platform 159 kg
Maximum occupants 1
SAFETY RULES
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Maintain safe distances from electrical power lines
and apparatus in accordance with applicable
governmental regulations and the following chart.
Voltage Minimum Safe
Phase to Phase Approach Distance
Meters
0 to 300V Avoid Contact
300V to 50KV 3.05
50KV to 200KV 4.60
200KV to 350KV 6.10
350KV to 500KV 7.62
500KV to 750KV 10.67
750KV to 1000KV 13.72
Allow for platform movement, electrical line sway or
sag and beware of strong or gusty winds.
Keep away from the machine if it contacts
energized power lines. Personnel on the ground or
in the platform must not touch or operate the
machine until energized power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.