29
VT04
To get the best performance from the Li-Ion battery, use these guidelines:
Do not store the Product on the charger for more than 24 hours as reduced
battery life may result.
Charge the Product for a 2-hour minimum at least every six months to
maximize battery life.
Without use, the battery will self-discharge in approximately 6 months.
Batteries stored for long periods may require two to ten charging cycles
before it reaches full capacity.
Always operate the Product within the operating temperature range in the
specifications.
Specifications
Temperature
Temperature Measurement Range..................... -10 °C to +250 °C
Temperature Measurement Accuracy ................ ±2 °C or ±2 % as tested (at 25 °C),
whichever is the greater
On-Screen Emissivity Correction ........................ Yes
On-Screen Reflected Background
Temperature Compensation ............................... Yes
Image Performance
Image Capture Frequency .................................. 8 Hz
Detector Type ..................................................... Uncooled pyroelectric ceramic
Thermal Sensitivity (NETD) ................................ 250 mK
Infrared Spectral Band ........................................ 6.5 µm to 14 µm
Visual Camera .................................................... 11025 pixels
Field of View
VT02 ............................................................... 20° X 20°
VT04A, VT04 .................................................. 28° X 28°
Focus Mechanism ............................................... Fixed Focus