Excell Precision High Precesion Counting Scale Scale User Manual


 
EXCELL PRECISION CO., LTD.
19
2-9 CHECK-WEIGHING
If the weight on the platter is over the preset weight, the beep will sound and the UNIT WEIGHT
(PER 1000) display will show
and flash.
SETTING MAXIMUM LIMIT OF WEIGHT:
(1) Press key (when the scale is loaded or unload).
®0¬
3
- - - -
Stable
3
the latest preset weight
(2) Key in the maximum limit (Use CE key to make any change).
®0¬
3
- - - -
Stable
3
The value of maximum weight (100=10.0)
F The weighing unit and decimal of the maximum weight value which you input should be same as
WEIGHT display.
(3) Press key (Use CE key to make any change).
®0¬
3
- - - -
Stable
3
(4) Press key, the scale will return to the counting mode.
®0¬
3
.
Stable
3
R