ESSICK EM-700S & 700P — PARTS & OPERATION MANUAL — REV. #8 (03/17/08) — PAGE 11
2) POLYETHYLENE DRUM MIXERS
The poly blade should come as close as possible to the surface
without touching. If material builds up on the drum, you may
use a rubber mallet to dislodge the material without adverse
effect to the drum.
IMPORTANT NOTICE
EPOXY COMPATIBILITY — There are some expoxies and
other chemicals used in certain applications that are not
compatible with polyethylene tubs.
Since Whiteman Industries cannot control the end user’s
application of this product, we will not assume responsibility
for the resulting damages when exposed to incompatible
chemicals.
CLEANING — BLADE ADJUSTMENTS
Always disconnect the spark plug wire before cleaning the inside
of the drum.
Never pour or spray water over the gasoline engine or electric
motor.
For consistent performance, long life and high quality mixing,
thoroughly clean the mixer inside and out at the end of each
day’s operation. To prevent lumps of dried mortar from forming
and contamination of future batches, do not allow a buildup of
materials to form on the blades or anywhere inside the drum.
The following is the recommended wiper blade adjustments:
1) STEEL DRUM MIXERS
SIDE SCRAPERSIDE SCRAPER
SIDE SCRAPERSIDE SCRAPER
SIDE SCRAPER
END SCRAPEREND SCRAPER
END SCRAPEREND SCRAPER
END SCRAPER
EM-700S & 700P — OPERATIONS