Citizen Systems CUN60 Blood Pressure Monitor User Manual


 
CH-311B
Compact palm top manual inflation
Blood Pressure Monitor
Function mark explanation
Digital Blood Pressure Monitors
9 10
Memory recall function
Easy-to-read LCD display
Compact & light weight
Automatic power off function
CH-302B
Compact manual inflation
Blood Pressure Monitor
Measurement System: Oscillometric method
Measurement range: Pressure; 0 280 mmHg
Pulse; 40 200 pulse/min
Accuracy: Pressure; 3 mmHg,
Pulse; 5 %
Power source: 6F22/9V 1
Battery life: Manganese battery: Approx. 400 times
Rated voltage: DC9V 0.1W : Direct Current
Outside dimensions: 85mm W 35mm H 120mm D
Weight: Unit: Approx. 110g without battery
Cuff: Approx. 150g
Pumping bulb unit: Approx. 40g
SPECIFICATIONS
90 memories function
Monthly average function
Simultaneous blood pressure and pulse reading
Soft cuff for comfortable use
Compact design for easy to carry
Automatic power off function
With compact storage case
CH-671F
Wrist measuring Automatic
Blood Pressure Monitor with
Time & Date and
Monthly average function
Measurement System: Oscillometric method
Measurement range: Pressure; 0 280mmHg
Pulse; 40 180 pulse/min
Accuracy: Pressure; 3 mmHg,
Pulse; 5 %
Power source: AAA size 2
Battery life: Alkaline battery: Approx. 300 times
Rated voltage: DC3V 1W : Direct Current
Outside dimensions: 59mm W 81mm H 24mm D
Weight: Approx. 100g without batteries
SPECIFICATIONS
Memory recall function
Simultaneous blood pressure and pulse reading
One handed operation
Easy-to-read LCD display
Automatic power off function
Measurement System: Oscillometric method
Measurement range: Pressure; 0 280 mmHg
Pulse; 40 180 pulse/min
Accuracy: Pressure; 3 mmHg,
Pulse; 5 %
Power source: AAA size 2
Battery life: Manganese battery: Approx. 700 times
Rated voltage: DC3V 0.1W : Direct Current
Outside dimensions: 66.5mm W 161.5mm H 44.5mm D
Weight: Unit: Approx. 110g without batteries
Cuff: Approx. 150g
SPECIFICATIONS
Memory recall function
Large LCD display
Large button
Automatic power off function
CH-308B
Easy operation manual inflation
Blood Pressure Monitor
Measurement System: Oscillometric method
Measurement range: Pressure; 0 280 mmHg
Pulse; 40 200 pulse/min
Accuracy: Pressure; 3 mmHg,
Pulse; 5 %
Power source: AA size 4
Battery life: Manganese battery: Approx. 1000 times
Rated voltage: DC6V 0.1W : Direct Current
Outside dimensions: 123mm W 44mm H 95mm D
Weight: Unit: Approx. 120g without batteries
Cuff: Approx. 150g
Pumping bulb unit: Approx. 40g
SPECIFICATIONS
Digital Blood Pressure Monitors
Wrist
Upper Arm / Semi-Automatic