Balance E 500KL Scale User Manual


 
Thank you for your purchase of this product. Please read this manual carefully and keep it handy for ready reference.
Merci d’avoir acheté ce produit. Veuillez lire attentivement ce manuel et le garder à portée de main pour pouvoir le
consulter à tout moment
Gracias por la adquisición de este producto. Lea por favor este manual cuidadosamente y manténgalo a su alcance
para una pronta referencia.
ENGLISH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FRANCAIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ESPANOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
TABLE OF CONTENTS
CAUTION AND WARNING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
SCALE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
STORAGE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
OPERATION INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
MODEL 500KL
To prevent injury and damage to your scale, please follow these instructions very carefully
Do not transport the scale while the platform is loaded.
For accurate weighing the scale must be placed on a flat, stable surface.
For accurate weighing, verify proper operation according to the procedure described in this manual before each use.
Do not use in the presence of flammable materials.
Operating at other voltages and frequencies than specified could damage the equipment.
If the “LOW BAT” indicator activates, for accurate weighing replace the batteries or connect the scale to an AC power source as soon as possible.
Only manufacturer’s qualified personnel shall service this scale.
This equipment has been tested and found to comply with the EMC limits for the Medical Device Directive 93/42/EEC (EN 55011 Class __ and EN 60601-1-2). These
limits are designed to provide reasonable protection against harmful interference in a typical medical installation. The equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to other devices in the vicinity. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference with other devices, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving device.
• Increase the separation between the equipment.
• Connect the equipment into an outlet on a circuit different from that to which the other device(s) is connected.
• Consult the manufacturer or field service technician for help.
Capacity and resolution
500lb x 0.2lb / 220kg x 0.1kg
Power Requirements Adapter Model ADPT31* 120VAC - 12VDC 60Hz 100mA or 6 - AA cell 1.5 V batteries
Environmental Operating temperatures: 50ºF to 104ºF / 10°C to 50°C
Atmospheric Pressure: 500hPa - 1060hPa
Humidity: 10% - 95% RH
Platform Dimensions:
16 1/2" x 14" x 2 1/2" / 42.3 cm x 35.6 cm x 5.8 cm
Scale Dimensions
21" x 14 3/4" x 53 1/2" / 53.5 cm x 37.5cm x 136cm
2
CAUTION AND WARNING
DEFINITION OF SYMBOLS
SCALE SPECIFICATIONS
Attention, Consult Accompany Documents
Type BF Applied Parts
AC to DC power supply
Temperature range
Humidity range
Atmospheric pressure range
AC to DC power supply
DC Connector Polarity
Storage Temperatures: 32ºF to 122ºF / 0°C to 50°C
Humidity: 10% - 95% RH
Atmospheric Pressure: 500hPa - 1060hPa
STORAGE SPECIFICATIONS
-10C
+50C
10%-95% RH
12V DC, 100mA
+
+
500hps
1060hps
*WARNING: For use with AC Adapter Model CSD1200100U-31/ADPT31 only.
Complies with C22.2 No. 601.1-M90 and UL Std No. 60601-1. Type BF applied parts.
Internally powered. Equipment not suitable for use in the presence of a flammable
anaesthetic mixture with air or with oxygen or nitrous oxide.
BALANCES.COM