AOSafety M-Tac Respiratory Product User Manual


 
Technical Questions?
U.S.A & Canada Other Countries
Phone: 1-800-444-4774 1-508-764-5721
Fax: 1-508-764-5640 1-508-764-5640
For ordering information or your
nearest stocking distributor:
U.S.A Canada Export Sales
Phone: 1-800-225-9038 1-800-387-9681 1-317-692-6643
Fax: 1-800-488-8007 1-800-488-8007 1-317-656-5827
Aearo Technologies • 8001 Woodland Drive • Indianapolis, IN 46278 © 2006 Aearo Technologies
AOSafety
®
is a registered trademark licensed to Aearo Technologies.
Shelf Life: 10 years (foil wrap, plugs)
Diameter:
4.25 inches (10.8 cm)
Height:
3 inches (7.6 cm)
Weight:
0.71 pounds (323 grams)
Connection:
40 mm NATO thread
Body Material:
Black polyamide
The Cartridge was tested by independent
labs to verify its performance against a range
of chemical warfare agents.
59200-00001 AOSafety M-Tac Respirator, Small
59201-00001 AOSafety M-Tac Respirator, Medium
59202-00001 AOSafety M-Tac Respirator, Large
59231-00000 AOSafety M-Tac Cartridge
59212-00000 Maintenance Kit
59213-00000 Head Harness
59215-00000 Storage/Carrying Case
59216-00000 Speech Capsule
59217-00000 Spectacle Kit
59219-00000 Bottle Cap and Bottle for Drinking Tube
Product Code Description
Chemical/Biological Protection For Law Enforcement & Emergency Responders
NEW
M-TAC RESPIRATOR
Lit# 34148A 8/06
DMMP (surrogate for GB)
Sarin (GB)
Cyanogen Chloride (CK)
Chloropicrin (PS)
Hydrogen Cyanide (AC)
Challenge Agent
Test
Concentration
3000 mg/m
3
4000 mg/m
3
4000 mg/m
3
15000 mg/m
3
5500 mg/m
3
Flow Rate
50 lpm
32 lpm
32 lpm
30 lpm
30 lpm
Breakthrough
Concentration
0.04 mg/m
3
0.04 mg/m
3
8.0 mg/m
3
0.7 mg/m
3
5.0 mg/m
3
Cartridge Testing Conditions and Results - Chemical Warfare Agents
Time to
Breakthrough
>210 minutes*
>215 minutes*
30 minutes*
70 minutes
45 minutes
Phosphine
Tear Gas (CS)
Tear Gas (CN)
Chlorine
Hydrogen Chloride
Sulfur Dioxide
Formaldehyde
Ammonia
Methylamine
Hydrogen Sulfide
Chlorine Dioxide
Hydrogen Fluoride
Gas Challenge
Test
Concentration
1500 ppm
3 ppm
16 ppm
500 ppm
500 ppm
500 ppm
100 ppm
1000 ppm
1000 ppm
1000 ppm
500 ppm
70 ppm
Flow Rate
64 lpm
64 lpm
64 lpm
64 lpm
64 lpm
64 lpm
64 lpm
64 lpm
64 lpm
64 lpm
64 lpm
64 lpm
Breakthrough
Concentration
0.3 ppm
0.05 ppm
0.05 ppm
5.0 ppm
5.0 ppm
5.0 ppm
1.0 ppm
50.0 ppm
10.0 ppm
10.0 ppm
0.1 ppm
3.0 ppm
Cartridge Testing Conditions and Results - NIOSH 42 CFR Part 84 Gases
(Toxic Industrial Materials)
Time to
Breakthrough
>24 minutes**
>480 minutes**
>480 minutes**
>35 minutes**
25 minutes**
>85 minutes**
>100 minutes**
>55 minutes**
>80 minutes**
>60 minutes**
>60 minutes**
>60 minutes**
* Note: These tests are part of the performance
specifications for the C2A1 canister, as specified
in military specification MIL-PRF-51560A (EA),
1 July 1997,Performance Specification: Canister,
Chemical-Biological Mask: C2A1. The Cartridge
meets or exceeds the performance requirements
of the C2A1 canister for these gases.
** Note: The Cartridge toxic industrial materials
(TIMs) performance exceeds the 42 CFR Part 84
minimum service life requirements for these gases.
In addition to protecting against toxic industrial
materials (TIMs) and the chemical warfare agents
listed above, the Cartridge offers particulate
protection that is over 99.97% efficient. The P100
filter removes all aerosols and solid particulates,
which makes it effective protection against a range
of weaponized biological agents.
TM