Allegro Industries 9821 Oxygen Equipment User Manual


 
4)
If there is a drop in outlet pressure:
Check if exhaust filter housing and canister is cross-threaded or not seated firmly onto housing gasket.
o Remove canister, inspect threads and gasket and reinstall.
Check for dirty inlet filter element.
o Replace if necessary.
Check if vanes are sticking or worn out.
o Flush pump with approved solvent.
o If unsuccessful, follow instructions under Disassembly, to check vane condition.
o Replace if necessary.
Check adjustment of pressure relief valve.
o Adjust if necessary.
AIR DRIVEN PUMP:
1.
If low torque or speed, or motor runs hot:
Check for dirt foreign material, rust, or a jammed machine.
Check for misalignment or poor lubrication.
Check for insufficient air pressure.
o Inspect interior of motor, remove contaminants or foreign objects.
o Realign motor, add lubricant to inline lubricator.
o Check source of air (compressor) for proper pressure and CFM settings and/or capability.
o Supply airline to the motor could be too small (1/2”I.D. minimum).
Ensure the exhaust is not restricted.
o Clean of debris or ice formed on muffler.
o If ice has formed on muffler, check for excess moisture in air supply.
o Make sure you use muffler extension.
If runs well, then slows down.
o Check for proper alignment, and realign.
o Make sure the exhaust port or muffler is not restricted.
o Make sure machine is not jammed
2.
If motor won’t turn at all:
Check for dirt, foreign material, rust, or a jammed machine.
Check for misalignment or poor lubrication.
Contact Allegro Technical Support Department.
WARNING!
Shut down pump and unplug before working on unit.
9