4
Fig. 4 Fig. 5
1. Prestretch top and bottom straps before placing respirator on the face (8210 only).
2. Cup the respirator in your hand, with the nosepiece at your fingertips, allowing the headbands to hang
freely below your hand.
3. Position the respirator under your chin with the nosepiece up. Pull the top strap over your head
resting it high at the top back of your head. Pull the bottom strap over your head and position it
around the neck below the ears.
4. Place your fingertips from both hands at the top of the metal nosepiece. Using two hands, mold the
nose area to the shape of your nose by pushing inward while moving your fingertips down both sides
of the nosepiece.
! Pinching the nosepiece using one hand may result in improper fit and less effective respirator
performance. Use two hands.
5. Perform a User Seal Check prior to each wearing. To check the respirator-to-face seal, place both
hands completely over the respirator and exhale. Be careful not to disturb the position of the
respirator. If air leaks around nose, readjust the nosepiece as described in step 4. If air leaks at the
respirator edges, work the straps back along the sides of your head. If you CANNOT achieve a proper
seal, DO NOT enter the contaminated area. See your supervisor.
Removal Instructions
See step 3 of Fitting Instructions and cup respirator in hand to maintain position on face. Pull bottom
strap over head. Still holding respirator in position, pull top strap over head and remove respirator.
NIOSH Approved: N95
At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil.