L
L
T
T
-
-
0
0
2
2
I
I
n
n
f
f
r
r
a
a
r
r
e
e
d
d
L
L
a
a
s
s
e
e
r
r
B
B
B
B
Q
Q
S
S
u
u
r
r
f
f
a
a
c
c
e
e
T
T
h
h
e
e
r
r
m
m
o
o
m
m
e
e
t
t
e
e
r
r
I
I
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
s
s
The LT-02 is a non-contact infrared thermometer, with Real-Time Maximum (MAX) temperature display.
Please remember to keep away from children and don’t use it for safety related applications.
Features:
o
C or
o
F
Press Mode key (○
2
) for
o
C or
o
F transferred.
Backlight LCD Backlight: always on.
Laser ClassII Laser: always enable while measuring.
EMC/RFI
Readings may be affected if the unit is operated within radio frequency electromagnetic field strength of
approximately 3 volts per meter, but the performance of the instrument will not be permanently affected.
* Note: Under the electromagnetic field of 3V/m from 350 to 550MHZ, the maximum error is 8°C (14.4°F).
CAUTION
1. WHEN DEVICE IS IN USE, DO NOT LOOK DIRECTLY INTO THE LASER BEAM–PERMANENT EYE DAMAGE
MAY RESULT.
2. USE EXTREME CAUTION WHEN OPERATING THE LASER.
3. NEVER POINT THE DEVICE TOWARDS ANYONE’S EYES.
4. KEEP OUT OF REACH OF ALL CHILDREN.
STORAGE & CLEANING
The sensor lens is the most delicate part of the thermometer. The lens should be kept clean at all times, care should
be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allowing the
lens to fully dry before using the thermometer. Do not submerge any part of the thermometer. The thermometer
should be stored at room temperature between –20 to +65°C (-4~149°F).
LCD ERROR MESSAGES
The thermometer incorporates visual diagnostic messages as follows:
「
」
「
」
‘Er2’ is displayed when the thermometer is exposed to rapid changes in the ambient temperature.
‘Er3’ is displayed when the ambient temperature exceeds 0
o
C(32°F) or +50
o
C (122°F).
The thermometer should be allowed plenty of time (minimum 30 minutes) to stabilize to the
working/room temperature.
「
」
For all other error messages it is necessary to reset the thermometer. To reset it, turn the
instrument off, remove the battery and wait for a minimum of one minute, reinsert the battery and
turn on. If the error message remains please contact the Service Department for further
assistance.
(Default Screen)
BATTERIES
The thermometer incorporates visual low battery indication as follows:
‘Battery OK’: measurements
are possible
‘Battery Low’: battery needs to be
replaced, measurements are still possible
‘Battery Exhausted’: measurements
are not possible
When the ‘Low Battery’ icon indicates the battery is low, the battery should be replaced immediately with AAA,
1.5V batteries. Please note: It is important to turn the instrument off before replacing the battery otherwise the
thermometer may malfunction. Dispose of used battery promptly and keep away from children.
SPECIFICATION
Measurement Range
-50 to +550
o
C (-58 to +1022
o
F)
Operating Range 0~50°C (32~122°F)
Accuracy, (Tobj=15-35°C,Tamb=25°C) +/-1.0°C (1.8°F)
Accuracy (Tobj=-33-400°C,Tamb=23 +/- 3°C) +/-2% of reading or 2°C (4°F) whichever is greater
Emissivity 0.95 fixed
Resolution (-9.9~199.9°C) 0.1°C/0.1°F
Response Time (90%) 1sec
Distance:Spot 9:1
Battery Life Typ.18, min 14 hours continuous use
Dimensions 175.2 x 39.0 x 71.9mm
Weight 179 grams including batteries (AAA*2pcs)
** The thermometer will automatically shut off if left idle for more than 15sec.
MAVERICK LIMITED 90 DAY WARRANTY
Maverick Industries Inc. warrants this product to be free of defects in parts, materials and workmanship for a period of 90 days, from date of purchase.
Should any repairs or servicing under this warranty be required, contact Maverick Customer Service by mail or phone for instructions on how to pack
and ship the product to Maverick's National Service Center located as follows:
Maverick Customer Service
94 Mayfield Ave.
Edison NJ 08837
Telephone: (732) 417-9666
Hours: Weekdays 8:30 AM- 4:30 PM
Do not send any parts or product to Maverick without calling and obtaining a Return Authorization Number and instructions.
This warranty is VOID if instructions for use are not followed; for accidental damage; for commercial use; for damage incurred while in transit; or if the
product has been tampered with.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
www.maverickhousewares.com
1. Simply aim the thermometer at the
target with Laser (
⑤) and press
trigger (○
6
) to display the surface
temperature.
2. During the measurement, the MAX
reading will be displayed beside the
icon.
3. The Distance:Spot is 9:1. Please make
sure the target area is within the field
of view.