TDK NB-59S-09S-0 Nebulizer User Manual


 
(1/4)
002-01 / 20080731 / ef441_nb.fm
• All specifications are subject to change without notice.
Ultrasonic Nebulizer Units
Incorporate Type
NB Series
The TDK ultrasonic humidifier unit was the first such product in the
world to be developed. There is an increasing need for indoor
humidification due to the proliferation of clean air heat pumps and
central heating systems.
When the appropriate amount of humidity is added as determined
by the relationship between humidity and sensible temperature
(temperature perceived by the body), humidification is advanta-
geous from the standpoint of both health and reduced energy con-
sumption.
In addition to such home uses, these ultrasonic humidifier units
have numerous advantages for humidification of vegetable show-
cases, preservation and growth of agricultural products, industrial
applications, etc. A wide variety of standard units are available
from TDK.
ELECTRICAL CHARACTERISTICS
The character at the end of the product number indicates the transducer’s direction of tilt.
EXAMPLE OF ATOMIZATION CHAMBER CONSTRUCTION TYPICAL TRANSDUCER INSTALLATION
TYPICAL CHARACTERISTICS OF HUMIDIFIER UNITS
VOLTAGE CHARACTERISTICS(48V) WATER TEMPERATURE CHARACTERISTICS(48V) WATER LEVEL CHARACTERISTICS
Part No. NB-514S-01-0 NB-59S-09S-0 NB-80E-01-H
Rated input voltage
Eac(V) 48±10% 48±10%
Edc(V) 12±10%
Power consumption (W) 30±5 30±5 13.2max.
Mist output ratio (l/h) (575±125)×10
–3
450×10
–3
min. (150+100, –50)×10
–3
Ultrasonic frequency (kHz) 1600 to 1750 1600 to 1750 2350 to 2600
Normal water level (mm) 40 40 35
External potentiometer (k)5 10
Operating water temperature range (°C) 0 to 45 0 to 45 0 to 45
Water quality Drinking water Drinking water Drinking water
Transducer element life (h) 10000 10000 5000
Cooling method Water cooled Water cooled Air cooled
Parallel connected operation Yes Yes Yes
Weight (g) 110 60 60
Main application Home Medical use
Air-flow
Mist
Mist discharge tube
Atomization chamber
Float switch
External potentiometer
for control of mist generation
Power transformer
Ultrasonic humidifier unit
Fan moter
Transducer
Drive
circuit
Water tank
35 to 45mm
13mm
Transducer
(tilted about 7˚)
(H means horizontal)
The arrows indicate the directions
of the various water jets.
Various tilt directions of the transducer
0
2
31
+40
+20
48V+10
(
52.8V
)
+20
(
57.6V
)
+30
(
62.4V
)
–20
(
38.4V
)
–10
(
43.2V
)
–30
(
33.6V
)
–60
–40
–20
Input voltage ratio
(
%
)
Mist generation
ratio(%)
[
0%=550
(
ml/hr
)]
700
600
500
Mist output
(
ml/hr
)
Water temperature
(
˚C
)
10 20 30 40 50
600
400
200
Mist output
(
ml/hr
)
Water level
(
mm
)
30 35 40 45 50
48V series
24, 12V series