HH806AW
MULTILOGGER THERMOMETER
OMEGAnet On-Line Service
omega.com
Internet e-mail
info@omega.com
Servicing North America:
U.S.A: One Omega Drive, Box 4047
Stamford, CT 06907-0047
ISO 9001
Tel: (203) 359-1660 FAX: (203) 359-7700
Certified e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec) H7L 5A1, Canada
Tel: (514) 856-6928 FAX: (514) 856-6886
e-mail: info@omega.ca
Forimmediate technical or application assistance:
U.S.A Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
and Customer Service: 1-800-622-2378/1-800-622-BEST
®
Canada:
Mexico: En Espan ol: (001) 203-359-7803
e-mail: espanol@omega.com
FAX: (001) 203-359-7807 info@omega.com.mx
Servicing Europe:
Benelux: Postbus 8034, 1180 LAAmstelveen, The Netherlands
Tel: +31 (0)20 3472121 FAX: +31 (0)20 6434643
Toll Free in Benelux: 0800 0993344
e-mail: sales@omegaeng.nl
Czech Frystatska 184, 733 01 Karviná, Czech Republic
Republic:
Tel: +420 (0)59 6311899 FAX: +420 (0)59 6311114
Toll Free: 0800-1-66342 e-mail: info@omegashop.cz
France:
11, rue Jacques Cartier, 78280 Guyancourt, France
Tel: +33 (0)1 61 37 2900 FAX: +33 (0)1 30 57 5427
Toll Free in France: 0800 466 342
e-mail: sales@omega.fr
Germany/ Daimlerstrasse 26, D-75392 Deckenpfronn, Germany
Austria:
Tel: + 49 (0)7056 9398-0 FAX: +49 (0)7056 9398-29
Toll Free in Germany: 0800 639 7678
e-mail: info@omega.de
United One Omega Drive, River Bend Technology Centre
Kingdom: Northbank, Irlam, Manchester
ISO 9002 M44 5BD United Kingdom
Certified Tel: +44 (0)161 777 6611 FAX: +44 (0)161 777 6622
Toll Free in United Kingdom: 0800-488-488
e-mail: sales@omega.co.uk
It is the policy of OMEGA Engineering, Inc. to comply with all
worldwide safety and EMC/EMI regulations that apply. OMEGA
is constantly pursuing certification of its products to the
European New Approach Directives. OMEGA will add the CE
mark to every appropriate device upon certification.
The information contained in this document is believed to be
correct, but OMEGA accepts no liability for any errors it
contains, and reserves the right to alter specifications without
notice.
These products are not designed for use in, and
should not be used for, human applications.
INTRODUCTION
The instrument is a portable digital thermometer that
measure
s external thermocouples of type K, J, R, S, T, E,
N. The thermocouples types comply with the N.I.S.T. –
IT
S 90 standard reference temperature/voltage tables.
Th
e thermometer features a dual thermocouple input, an
adjustabl
e T/C offset and an USB interface for uploading
data to a PC using optional software and cable.
SAFETY INFORMATION
WARNING
To avoid electrical shock, do not use this instrument
when working voltages at the measurement surface
over 24V AC or DC.
WARNING
To avoid damage or burns, do not make temperature
measurement in microwave ovens.
CAUTION
Repeated sharp flexing can break the thermocouple
leads. To prolong lead life, avoid sharp bends in the
leads, especially near the connector.
FEDERAL COMMUNICATIONS
COMMISSION
This device complies with Part 15 of the FCC Rules.
Operatio
n is subject to the following two condi-
tions:(1
) this device may not cause harmful interfer-
ence
, and (2) this device must accept any interference
received
, including interference that may cause unde-
sired operation.
NOTE
This equipment has been tested and found to comply
wit
h the limits for a Class B digital device, pursuant to
Par
t 15 of the FCC Rules. These limits are designed to
provid
e reasonable protection. This equipment gener-
ates
, uses and can radiate radio frequency energy and,
if not installed and used in accordance with the in-
structions
, may cause harmful interference to radio
communications
. However, there is no guarantee that
interferenc
e will not occur in a particular installation If
thi
s equipment does cause harmful interference to ra-
dio or television reception, which can be determined
by turning the equipment off and on, the user is en-
couraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and
receiver
.
- Connect the equipment into an outlet on a circuit dif-
ferent from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV tech-
nician for help.
Shielde
d interface cables must be used in order to
comply with emission limits.
comply with emission limits.
Change
s or modifications not expressly approved by
th
e party responsible for compliance could void the
user‘s authority to operate the equipment.
WIRELESS NOTE
Wireless receiver must keep a distance of at least 30cm
from the meter and meter to meter distance must be at
Celsius or Fahrenheit user-selectable
least 20cm.
SPECIFICATIONS
ELECTRICAL
Measurement Range:
K-TYPE (0.1°) -200°C to 1372°C (-328°F to 2501°F)
J-TYPE (0.1°) -210°C to 1200°C (-346°F to 2192°F)
T-TYPE (0.1°) -200°C to 400°C (-328°F to 752°F)
E-TYPE (0.1°) -210°C to 1000°C (-346°F to 1832°F)
R-TYPE (1°) 0°C to 1767°C (32°F to 3212°F)
S-TYPE (1°) 0°C to 1767°C ( 32°F to 3212°F)
N-TYPE (0.1°) -50°C to 1300°C ( -58°F to 2372°F)
*Based on the ITS-90 temperature standard.
According to temperature standard ITS-90.
Accuracy:
K/J/T/E-TYPE
±(0.05% rdg + 0.3°C) on -50°C to 1372°C
±(0.05% rdg + 0.7°C) on -50°C to -210°C
±(0.05% rdg + 0.6°F) on -58°F to 2501°F
±(0.05% rdg + 1.4°F) on -58°F to -346°F
N-TYPE
±(0.05% rdg + 0.8°C) on -50°C to 0°C
±(0.05% rdg + 0.4°C) on 0°C to 1300°C
±(0.05% rdg + 1.6°F) on -58°F to 32°F
±(0.05% rdg + 0.8°F) on 32°F to 2372°F
R/S-TYPE
±(0.05% rdg + 2°C) on 0°C to 1767°C
±(0.05% rdg + 4°F) on 32°F to 3212°F
Temperature Coefficient:
0.1 times the applicable accuracy specification per °C
from 0°C to 18°C and 28°C to 50°C (32°F to 64°F and
82°F to122°F).
Input Protection:
24V dc or 24V ac rms maximum input voltage on any
combination of input pins.
Reading Rate: 2.5 time per second.
Wireless Features:
Frequency range: 910~920MHz
Low current consumption less than 1mA
Th
e transmitting distance can reach 25M without
netic interference.
External Connections:
1. USB Port
2. DC power JACK(12V)
ENVIRONMENTAL
Ambient Operating Ranges:
M4553/0907
Shop online at: omega.com e-mail: info@omega.com
For latest product manuals: omegamanual.info
INSTRUCTION
SHEET
1
2