PRODUCT DESCRIPTION
The Model DXS-64 is a battery powered, miniature, water-resistant*, supervised
transmitter designed for use in emergency applications with Linear’s DX and DXS
format receivers. The transmitter is supplied with an adjustable lanyard with a
breakaway release. Pressing the button on the transmitter sends a digital coded
wireless signal to its companion receiver. To insure sending a complete
signal, press the transmitter button for a minimum of two
seconds.
The DXS-64 transmitter is factory set to a unique code, so no fi eld coding is
required. The DXS-64 sends a signal when its button is pressed. The transmitter
can send a signal for up to 30 seconds per activation. The red signal indicator on
the transmitter lights when the unit is activated.
If status transmissions are enabled, they will be sent every two hours. Some
receivers are able to use these signals, others are not.
Every two hours the transmitter tests for a low battery. This test takes place even if
status transmissions have not been enabled. If the battery tests low, a low battery
signal is sent and the transmitter LED fl ashes.
Receivers must be programmed to the transmitter’s code before system testing
and operation. Refer to the receiver’s instructions for details on operation and
programming.
Each transmitter is sealed to provide water-resistance. The unit’s battery is not
replaceable. The transmitter should be discarded at the end of its battery life.
* NOTE: Water resistance not tested by UL
FEATURES
STATUS OPTION & PROGRAMMING SYSTEM TESTING LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twenty-four (24) months.
This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s
normal distribution channels. Linear does not warrant this product to consumers. Consumers should
inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations
or liabilities on the part of Linear LLC for consequential damages arising out of or in connection
with use or performance of this product or other indirect damages with respect to loss of property,
revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including
implied warranties for merchantability and implied warranties for fi tness, are valid only until the warranty
expires. This Linear LLC Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact
Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless
signaling. However, there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as
Part 15 devices. As such, they have limited transmitter power and therefore limited range.
A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio
signals that occur on or near their operating frequencies, regardless of code settings.
Changes or modifi cations to the device may void FCC compliance.
Infrequently used radio links should be tested regularly to protect against undetected interference or
fault.
A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
distributor or dealer, and these facts should be communicated to the ultimate users.
This device complies with FCC Part 15 and Canada Rules and Regulations. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference and (2) this device must
accept any interference received, including interference that may cause undesired operation.
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 - Toll Free FAX (800) 468-1340
www.linearcorp.com
Copyright © 2012 Linear LLC 224801 D
IF THE TWO HOUR STATUS TIMER IS DESIRED FOR SUPERVISION,
PERMANENTLY ENABLE THE TIMER BY PRESSING THE TRANSMITTER
BUTTON FIVE TIMES IN SUCCESSION WITHIN 3 TO 4 SECONDS.
WHEN
STATUS REPORTING IS TURNED ON, THE LED SIGNAL INDICATOR WILL
BLINK RAPIDLY DURING ACTIVATION.
PROGRAM THE TRANSMITTER INTO THE RECEIVER BY PLACING THE
RECEIVER INTO PROGRAM MODE. THEN SEND A SIGNAL TO THE RECEIVER
FROM THE TRANSMITTER. REFER TO THE RECEIVERS PROGRAMMING
INSTRUCTIONS FOR DETAILS.
THE MANUFACTURER STRONGLY RECOMMENDS THAT YOU TEST
SECURITY EQUIPMENT FREQUENTLY. OVER A PERIOD OF TIME,
NO ELECTRONIC PRODUCT IS BETTER THAN THE INSPECTION
AND MAINTENANCE IT RECEIVES. THEREFORE, FROM THE TIME
OF INSTALLATION, IT IS ABSOLUTELY NECESSARY TO TEST THE
SYSTEM AT LEAST ONCE A WEEK.
IMPORTANT! TEST SYSTEM WEEKLY
PLACE THE RECEIVER IN "TEST" MODE
AND ACTIVATE THE TRANSMITTER.
VERIFY THAT THE SIGNAL IS RECEIVED
AND THAT THE SYSTEM REPORTS AS
REQUIRED.
A SLOW BLINKING SIGNAL
INDICATOR MEANS THE
BATTERY IS LOW AND THE
DXS-64 NEEDS TO BE
REPLACED
LANYARD
BREAKAWAY
RELEASE
SIGNAL
INDICATOR
ACTIVATION
BUTTON
LENGTH
ADJUSTER
BY
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,DXS-64 - LINEAR P/N: 224801 D - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500” X 5.500” - FOLDING: 3 FOLD ALTERNATE, FINISH WITH LOGO SHOWING - SCALE: 1-1