ATD5496
MeterCalibration
z Itisstronglyrecommendedthatthefollowingstepsshouldonlyperformbyprofessional
people.
z Pleasewearsafetygogglesandglovesbeforeperformingthefollowingprocedures.
z Thefollowingproceduresshouldonlybeperformedwhenthemeterreadingistestedand
confirmedoutofaccuracy.
1.Test
abatterybyDVOMandrecordthevoltage.Thisvoltagewillbeconsideredasthestandard
voltageinthefollowingadjustment.Soitisimportanttomakesurethevoltageiscorrect.
2DisassembletheATD5496youcanfindayellowcalibrationscrewonbackofPCBboard(Fig...).
The
adjustmentcanbemadebyturningthiscalibrationscrew.
2.1ConnectthebatterytoATD5496,andatthemeantime,turnthecalibrationscrewuntilneedle
pointstothestandardvoltage.(i.e.ifstandardvoltageis12.4V,adjusttheneedleto12.4V)
2.2 Disconnectbattery andthen reconnect battery to make sure that the readout is same as
standardvoltage.Ifnot,needrepeatstep2.1.Ifyes,thecalibrationisfinished.