A&D DT-102 Thermometer User Manual


 
Digital thermometer instructions – moDel Dt-102
Congratulations on your purchase of this A&D Medical Digital
Thermometer. Please read the instructions carefully to ensure
accurate temperatures and safe operation. When used properly, this
high quality product will give you years of accurate, dependable
service.
SAFETY INFORMATION
☞
High, prolonged fever requires medical attention (over 100.0°F
or 37.8°C) for young children. In case of high readings, please
contact your physician.
☞
Do not allow children to take their temperature unattended.
☞
Read the enclosed instructions carefully to ensure accurate
temperature readings.
☞
Temperature readings are affected by many factors including
exercise, drinking hot or cold beverages prior to taking, and
technique.
☞
Do not allow children to walk or run during temperature
taking. The rigid probe could present a hazard.
☞
Oral, underarm, and rectal temperatures vary by approxi-
mately 1°F (0.5°C).
SPECIAL PRODUCT FEATURES
Memory feature: automatic recall of last temperature reading.
Beeps when peak temperature is reached.
Auto-Off in approximately 10 minutes.
Thermometer is water resistant, but not 100% waterproof. Do not
submerge unit in any liquid.
Long-life, replaceable battery (approximately 2,000 temperatures).
Low Battery Indicator “ ”.
Oral, Rectal or Underarm use.
HOW TO CARE FOR THIS PRODUCT
The thermometer should be cleaned after every use even when
probe covers are used.
Clean the thermometer tip and probe using isopropyl alcohol or
soap and water.
Do not boil the thermometer. Do not submerge the thermometer
in any liquid.
Store the unit in the protective case while not in use.
Do not store or keep in direct sunlight, or in high temperatures.
Do not open the thermometer except to replace the battery.
Do not drop the thermometer, as this may break the unit.
Do not attempt to disassemble the unit except to replace the
battery.
WHAT IS A “NORMAL” TEMPERATURE?
Temperature readings vary among individuals. A normal
temperature refers to each individual’s average temperature
while they are well. Normal average temperatures range from
97°F/36.1°C to 100°F/37.7°C when taken orally. A rectal temperature
is considered your real or “core” body temperature. A rectal
temperature is 1°F/0.5°C higher than an oral reading and an
underarm temperature is 1°F/0.5°C lower than an oral reading.
HOW TO TAKE TEMPERATURE
1. Select oral, underarm or rectal as your measurement site (see
following instructions).
2. Push the ON/OFF button. The thermometer will beep and the
display will show all symbols. This is a function check indicating
the unit is working properly. If a previous reading is stored in
memory, the thermometer will display the last temperature for
two seconds. The flashing symbol °F will appear with the “L”
or “H” symbol indicating that the thermometer is ready for
measurement. Begin measurement.
3. When the °F symbol stops flashing and the thermometer emits
four beeps, the temperature measurement is complete.
4. Read and record the temperature and time for reference. The
reading will automatically be stored in the memory until
another reading is taken or the batteries are removed from the
thermometer.
5. Push the ON/OFF button to turn the unit off. If you do not turn
the unit off, it will shut off automatically in approximately 10
minutes.
ORAL USE
Do not drink hot or cold fluids, exercise,
smoke or perform other activities that raise
or lower temperature directly prior to taking
reading.
The mouth should remain closed up to 5
minutes before attempting a reading.
Place the probe tip well under the tongue in
locations as indicated by the “ ” (see
diagram). Instruct children not to bite down on the probe.
The approximate measurement time is 60 seconds. Opening the
mouth or improper placement of the probe tip may result in a
longer time for a reading.
UNDERARM (AUXILIARY) USE
From a medical point of view, this method
will always give an inaccurate reading and
should not be used if a precise measurement
is required.
Wipe underarm with a dry towel.
Place probe tip in armpit and bring arm
down against the body. The measuring sensor should be pointing
upward parallel to the arm.
The approximate measurement time may be 2 minutes or longer
depending on the placement of the probe and closure of the arm
against the body.
RECTAL USE
Commonly used for babies, young children or when it is difficult
to take an oral or underarm temperature.
After placing the probe cover on the thermometer, lubricate with
a water-soluble jelly such as K-Y Jelly®.
Gently insert the probe tip no more than 1/2 inch or 1.3 cm into
the rectum. Do not force the tip into the rectum if resistance is
encountered.
Wash the thermometer as recommended.
Approximate measurement time is 40 to 60 seconds.
Once used rectally, the thermometer should not be used orally for
sanitary reasons.
CLEANING INSTRUCTIONS
Wash the area extending about 2” from the tip with warm, soapy
water after each use and dry thoroughly.
OR
Wipe the area extending about 2” from the tip with 70% isopropyl
alcohol after each use.
NOTE: Do not submerge the thermometer in any liquid.
CHANGING THE BATTERY
When the ” appears and blinks, the battery needs to be
replaced. Make sure you use the same type of battery and proceed
as follows: Remove battery compartment lid. Use a non metal
probe to remove battery. Insert new equivalent battery type (1.5V or
LR41). Ensure battery is correctly positioned with the “+” facing up.
Carefully replace the battery compartment lid. Properly dispose of
the battery, keeping it from small children and heat.
CHANGING BETWEEN FAHRENHEIT & CELSIUS
1. This thermometer shows all results in Fahrenheit (F°).
2. To convert results shown in F° to Celsius (C°) use the following
equation:
C° = 5/9 x (F°- 32)
3. Here is a helpful chart showing some Fahrenheit and Celsius
equivalences:
90.0°
32.2°
92.0°
33.3°
94.0°
34.4°
96.0°
35.6°
98.0°
36.7°
100.0°
37.8°
102.0°
38.9°
104.0°
40.0°
106.0°
41.1°
108.0°
42.2°
SPECIFICATIONS
RANGE ...........................89.6°F - 107.6°F (32.0°C - 42.0°C)
ACCURACY MEASUREMENT .......
± 0.2°F for 95.9°F to 107.6°F
RANGE
± 0.4°F less than 95.9°F
± 0.4°F above 107.6°F
± 0.1°C for 32.0°C to 42.0°C
± 0.2°C less than 32.0°C
± 0.2°C above 42.0°C
STORAGE RANGE .................
-13°F to 131°F (-25°C to 55°C)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . when stored ≤ 95% RH
DISPLAY ..........................0.1°F (0.1°C)
BATTERY ..........................
One 1.5V button size battery
BATTERY LIFE .....................
Approximately 100 hours of
continuous operation
DIMENSIONS. . . . . . . . . . . . . . . . . . . . . .
6.0” x 1.0” x 0.8”
(15.2 x 2.5 x 2.0 cm)
WEIGHT ..........................
Approximately 17 grams
including battery
LEGAL REQUIREMENTS AND GUIDELINES
This product complies with the European Directive for Medical
Devices 93/42/EEC and carries the CE mark. The device also
complies with the specifications of the European Standard for clinical
thermometers-Part 3:
Performance of compact electrical thermometers (non-predictive and
predictive) with maximum device. The CE marking confirms that
this is a medical device with a measuring function in the sense of the
Medical Devices Act, which has undergone a conformity assessment
procedure. A Notified Body confirms that this product fulfills all the
appropriate statutory regulations.
COMPLIANCE
Product disposal instructions for electronic devices
The battery in this product complies with the requirements
stated in European Directives 2006/66/EEC.
Type B equipment
This device conforms to the European Directive 93/42 EEC
for Medical Products.
WARRANTY
A&D Medical warrants to the first retail purchaser that this digital
thermometer is free from defects in material and workmanship
for two years from date of purchase. This warranty does not cover
batteries or damage resulting from improper handling or use. To
obtain replacement product, please return the product, freight and
insurance prepaid, together with proof of purchase and applicable
shipping costs to A&D Medical at the address below. Call the toll-
free A&D Medical Health Line at 1-888-726-9966 for shipping costs
and further information. At A&D Medical’s option, the product will
be replaced with a new or refurbished product of equal value. THE
WARRANTY AND REMEDY PROVIDED ABOVE ARE EXCLUSIVE
AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. Some
states may have laws which amend this warranty.
CONTACT INFORMATION
Our products are designed and manufactured using the latest
scientific and technological methods, and offer accurate, easy to
use, home monitoring and treatment options. Our full product line
includes:
Digital Blood Pressure Monitors Personal Health Scales
Manual Blood Pressure Monitors Activity Monitors
Blood Pressure Cuffs Digital Thermometers
Wireless Products Stethoscopes
This A&D blood pressure product is covered by a two year warranty.
Distributed by:
A&D Engineering, Inc.
1756 Automation Parkway
San Jose, CA 95131
1-888-726-9966
www.andmedical.com
©2012 A&D Medical. All rights reserved. Specifications subject to change
without notice. I-MAN-DT-102-082012-REV-a
Printed in China